Products/Sewage/Z 0.75-7.5 kW 2P

Z SERIES · TWO-POLE SUBMERSIBLE SEWAGE PUMP

Z 0.75-7.5 kW 2P sewage pump range

One product family with 18 hydraulic selections, 18 exact catalog codes and 27 current configurations. Matching SF float-switch codes remain outside the page count.

0.75-7.5 kW · 18 models · 27 configurations

POWER1.0-10.1HPOUTLET50-100mmMAX FLOW581.2GPMMAX HEAD134.5ft
MEUDY Z 100Z27.5 two-pole sewage pump
Current catalog image assigned to 100Z25.5 and 100Z27.5 · shared across 50/60 Hz records

Series Overview

Key specifications shared across the Z 0.75-7.5 kW series.

R / Y / ZSoft pipe, hard pipe or auto-coupled
50 / 60 Hz3000 / 3600 rpm synchronous speed
8 mCable length
10 mMaximum immersion depth

Published data specifies IP68 protection, class F insulation, water temperature up to 40°C, pH 6-10 and three-phase 380 V +/-10% at both frequencies. The S and SF configurations shown in this entry use single-phase 220 V.

Model Range

Compare hydraulic performance across all available power ratings.

Eighteen performance selections, 50 Hz and 60 Hz separated. Each frequency cell shows rated flow / head and maximum flow / head in GPM / ft. Published data marks two 80 mm models unavailable at 60 Hz.

ModelMotor
HP
Outlet
mm
50 Hz rated / max
GPM / ft
60 Hz rated / max
GPM / ft
Cable
mm²
50Z2.751.05010 / 10
24 / 14
10 / 10
24 / 14
1.0
50Z2.75S1.05010 / 10
24 / 14
10 / 10
24 / 14
1.0
50Z21.11.55015 / 10
27 / 17
15 / 10
27 / 17
1.0
50Z21.1S1.55015 / 10
27 / 17
15 / 10
27 / 17
1.0
50Z21.52.05015 / 15
34 / 20
15 / 14
34 / 20
1.0
65Z21.52.06525 / 10
38 / 20
25 / 10
38 / 20
1.0
50Z22.23.05015 / 20
42 / 25
15 / 18
37 / 25
1.0
65Z22.23.06525 / 17
50 / 25
25 / 14
42 / 25
1.0
80Z22.23.08040 / 10
62 / 20
Not available
Not available
1.0
50Z23.04.05015 / 25
48 / 29
15 / 25
43 / 29
1.5
65Z23.04.06525 / 21
57 / 29
25 / 21
50 / 29
1.5
80Z23.04.08040 / 14
70 / 26
Not available
Not available
1.5
65Z24.05.46530 / 22
62 / 32
30 / 20
62 / 32
1.5
80Z24.05.48040 / 19
75 / 30
40 / 17
68 / 30
1.5
80Z25.57.48040 / 23
95 / 32
40 / 23
85 / 34
2.5
100Z25.57.410065 / 17
112 / 32
65 / 15
100 / 34
2.5
80Z27.510.18040 / 28
105 / 37
40 / 31
90 / 41
2.5
100Z27.510.110065 / 23
132 / 37
65 / 23
105 / 41
2.5

For each frequency column, the first line is rated flow / head and the second line is maximum flow / head. 80Z22.2 and 80Z23.0 are not available for 60 Hz.

MEUDY Z 50Z2.75, 50Z2.75S, 50Z21.1, 50Z21.1S sewage pump catalog image

50 MM STANDARD / S · 0.75-1.1 KW

50Z2.75 / 50Z2.75S / 50Z21.1 / 50Z21.1S

One of seven content-distinct catalog images; the listed exact codes share this assignment.
MEUDY Z 50Z2.75SF, 50Z21.1SF sewage pump catalog image

50 MM SF FLOAT SWITCH · 0.75-1.1 KW

50Z2.75SF / 50Z21.1SF

One of seven content-distinct catalog images; the listed exact codes share this assignment.
MEUDY Z 50Z21.5, 50Z22.2, 50Z23.0 sewage pump catalog image

50 MM · 1.5-3.0 KW

50Z21.5 / 50Z22.2 / 50Z23.0

One of seven content-distinct catalog images; the listed exact codes share this assignment.
MEUDY Z 65Z21.5, 65Z22.2, 65Z23.0, 65Z24.0 sewage pump catalog image

65 MM · 1.5-4.0 KW

65Z21.5 / 65Z22.2 / 65Z23.0 / 65Z24.0

One of seven content-distinct catalog images; the listed exact codes share this assignment.
MEUDY Z 80Z22.2, 80Z23.0, 80Z24.0 sewage pump catalog image

80 MM · 2.2-4.0 KW

80Z22.2 / 80Z23.0 / 80Z24.0

One of seven content-distinct catalog images; the listed exact codes share this assignment.
MEUDY Z 80Z25.5, 80Z27.5 sewage pump catalog image

80 MM · 5.5-7.5 KW

80Z25.5 / 80Z27.5

One of seven content-distinct catalog images; the listed exact codes share this assignment.
MEUDY Z 100Z25.5, 100Z27.5 sewage pump catalog image

100 MM · 5.5-7.5 KW

100Z25.5 / 100Z27.5

One of seven content-distinct catalog images; the listed exact codes share this assignment.

Configurations

Available 50 Hz / 60 Hz electrical configurations for each model.

Counted page codes are the base and S forms (18 codes, 27 frequency records). Matching SF float-switch codes (50Z2.75SF, 50Z21.1SF) are not added to this count. Counted records split across 50 Hz and 60 Hz with gaps kept visible. Raw outlet gaps and published/catalog differences are not silently filled.

Exact codeHzPhase / VPower
HP
Outlet
mm
Rated flow / head
GPM / ft
Max flow / head
GPM / ft
Drawing
50Z2.75503 / 3801.0-44.0 / 32.8106.1 / 46.6View
50Z2.75S501 / 2201.0-44.0 / 32.8105.7 / 46.3View
50Z2.75S601 / 1151.05044.0 / 32.8105.7 / 45.6View
50Z21.1503 / 3801.5-66.0 / 32.8118.9 / 55.1View
50Z21.1S501 / 2201.5-66.0 / 32.8118.9 / 56.8View
50Z21.1S601 / 1151.55066.0 / 32.8118.9 / 56.8View
50Z21.5503 / 3802.0-66.0 / 49.2149.7 / 66.3View
50Z21.5603 / 3802.05066.0 / 45.9150.1 / 65.6View
65Z21.5503 / 3802.0-110.1 / 32.8167.3 / 66.3View
65Z21.5603 / 3802.065110.1 / 32.8167.3 / 66.3View
50Z22.2503 / 3803.0-66.0 / 65.6184.9 / 83.7View
65Z22.2503 / 3803.0-110.1 / 55.8220.1 / 82.7View
65Z22.2603 / 3803.065110.1 / 45.9184.9 / 84.3View
80Z22.2503 / 3803.0-176.1 / 32.8273.0 / 70.9View
50Z23.0503 / 3804.0-66.0 / 82.0211.3 / 97.8View
65Z23.0503 / 3804.0-110.1 / 68.9251.0 / 96.5View
65Z23.0603 / 3804.065110.1 / 68.9220.1 / 99.4View
80Z23.0503 / 3804.0-176.1 / 45.9308.2 / 85.6View
65Z24.0503 / 3805.4-132.1 / 72.2273.0 / 103.0View
80Z24.0503 / 3805.4-176.1 / 62.3330.2 / 99.7View
80Z24.0603 / 3805.480176.1 / 55.8299.4 / 101.7View
80Z25.5503 / 3807.4-176.1 / 75.5418.3 / 104.3View
100Z25.5503 / 3807.4-286.2 / 55.8493.1 / 104.7View
100Z25.5603 / 3807.4100286.2 / 49.2440.3 / 110.6View
80Z27.5503 / 38010.1-176.1 / 91.9462.3 / 121.7View
100Z27.5503 / 38010.1-286.2 / 75.5581.2 / 121.1View
100Z27.5603 / 38010.1100286.2 / 75.5462.3 / 130.6View

Current catalog gaps: 50Z2.75, 50Z21.1, 50Z22.2, 80Z22.2, 50Z23.0, 80Z23.0, 65Z24.0, 80Z25.5 and 80Z27.5 have no 60 Hz record. All 50 Hz outlet fields are empty. For 100Z27.5 at 60 Hz, published data lists 135 ft maximum head while the catalog states 131 ft. Confirm before quotation.

Dimension drawing for MEUDY 100Z27.5 50 Hz configurationRepresentative catalog drawing · 100Z27.5 · 50 Hz

Construction

Cast-iron body, high-chrome wet-end parts.

Discharge / pump body
Cast iron / cast iron
Motor body / covers
Cast iron / cast iron
Impeller / inlet plate
High chrome alloy / high chrome alloy
Rotor shaft
AISI 304 stainless steel
Bearings
Ball bearings
Mechanical seal
SiC-SiC / carbon-ceramic

SOURCE & REVIEW

Evidence stays tied to this Z entry.

01

Published source

MEUDY sewage pump catalog 2026.6.6, printed pages 70-73 with specifications, materials, 50/60 Hz curves, R/Y dimensions and Z auto-coupling dimensions.

02

Current catalog

Twenty-seven counted frequency records come from current English Z base and S codes; SF float options remain outside the count.

03

Confirmation

Missing 60 Hz records, empty 50 Hz outlets, the 100Z27.5 head conflict, certification scope and North American suitability require confirmation.

Z SERIES FAQ

Selection questions answered from evidence.

How many models are in the Z 0.75-7.5 kW 2P range?

Published data groups 18 hydraulic selections in one Z product entry. Counted page codes are the base and S forms (18 codes, 27 frequency records). Matching SF float-switch codes 50Z2.75SF and 50Z21.1SF remain outside that count.

What do the S and SF codes mean on this page?

Published data table identifies the S rows as single-phase 220 V and explicitly states that Z...SF is single phase with a float switch. This page does not apply that suffix rule to other pump families.

Does every Z model have a current 60 Hz catalog record?

No. The current catalog has 11 matching 60 Hz records. Nine exact codes have no 60 Hz record, and published data specifically marks 80Z22.2 and 80Z23.0 as unavailable for 60 Hz.

Why do 50 Hz outlet cells show a dash?

All counted 50 Hz catalog records leave outlet diameter empty, while counted 60 Hz records list 50, 65, 80 or 100 mm. Published data outlet values remain visible in the hydraulic table.

Why is the 100Z27.5 maximum head flagged?

Published data lists 135 ft maximum head at 60 Hz, while the current 100Z27.5 60 Hz catalog record states 131 ft. Confirm the quotation value against an approved curve.

Continue from published data to a reviewed selection

Confirm frequency, outlet and duty point.