Products/Sewage/C 2.2-7.5 kW 4P Type T

C SERIES · TYPE T FOUR-POLE SEWAGE PUMP

C 2.2-7.5 kW 4P Type T sewage pump

One product family with six hydraulic models and nine current 50/60 Hz catalog configurations.

Published pages 67-69 · 6 exact codes · 9 catalog configurations

POWER3.0-10.1HPOUTLET80-100mmMAX FLOW660.4GPMMAX HEAD82.0ft
MEUDY C 100C47.5T four-pole Type T sewage pump
Current catalog image assigned to 100C45.5T and 100C47.5T · current records are 50 Hz only

Series Overview

Key specifications shared across the C 2.2-7.5 kW 4P Type T series.

Y / ZHard pipe or auto-coupled
Built inMotor protection
8 mCable length
20 mMaximum immersion depth

Published data specifies IP68 protection, class F insulation, three-phase 380 V +/-10% at 50 Hz and 60 Hz, water temperature up to 40°C and pH 6-10. Current matching catalog records retain that phase and voltage, but three model-frequency records are missing.

Model Range

Compare hydraulic performance across all available power ratings.

Six published models, 50 Hz and 60 Hz side by side. Rated and maximum columns show flow / head in GPM / ft. Missing catalog frequencies do not remove published values.

ModelMotor
HP
Outlet
mm
50 Hz rated / max
GPM / ft
60 Hz rated / max
GPM / ft
Passage
mm
Cable
mm²
80C42.2T3.08040 / 8
70 / 13
40 / 8
70 / 14
501.5
100C42.2T3.010040 / 8
95 / 13
40 / 8
95 / 14
501.5
80C43.7T5.08060 / 11
90 / 16
60 / 11
85 / 18
551.5
100C43.7T5.010060 / 11
125 / 16
60 / 11
120 / 18
551.5
100C45.5T7.410065 / 13
135 / 20
65 / 13
135 / 22
552.5
100C47.5T10.110080 / 15
150 / 24
80 / 15
150 / 25
554.0

For each frequency column, the first line is rated flow / head and the second line is maximum flow / head.

MEUDY C 80 mm outlet · 2.2-3.7 kW four-pole Type T sewage pump

80 MM OUTLET · 2.2-3.7 KW

80C42.2T / 80C43.7T

One distinct catalog image is shared by the listed model and frequency records.
MEUDY C 100 mm outlet · 2.2-3.7 kW four-pole Type T sewage pump

100 MM OUTLET · 2.2-3.7 KW

100C42.2T / 100C43.7T

One distinct catalog image is shared by the listed model and frequency records.
MEUDY C 100 mm outlet · 5.5-7.5 kW four-pole Type T sewage pump

100 MM OUTLET · 5.5-7.5 KW

100C45.5T / 100C47.5T

One distinct catalog image is shared by the listed model and frequency records.

Configurations

Available 50 Hz / 60 Hz electrical configurations for each model.

Three 60 Hz records are missing, and one model has a material maximum-flow difference from published data.

Exact codeHzPhase / VPower
HP
Outlet
mm
Rated flow / head
GPM / ft
Max flow / head
GPM / ft
Drawing
80C42.2T503 / 3803.080176.1 / 26.2308.2 / 43.3View
100C42.2T503 / 3803.0100176.1 / 26.2418.3 / 42.7View
100C42.2T603 / 3803.0100176.1 / 26.2418.3 / 45.6View
80C43.7T503 / 3805.080264.2 / 36.1396.3 / 53.1View
80C43.7T603 / 3805.080264.2 / 36.1374.2 / 60.4View
100C43.7T503 / 3805.0100264.2 / 36.1559.2 / 53.1View
100C43.7T603 / 3805.0100264.2 / 36.1490.0 / 60.4View
100C45.5T503 / 3807.4100286.2 / 42.7594.4 / 65.9View
100C47.5T503 / 38010.1100352.2 / 49.2660.4 / 79.4View

Current catalog gaps: 80C42.2T, 100C45.5T and 100C47.5T have no 60 Hz record. For 100C43.7T, published data lists 125 / 528 GPM maximum flow at 50 / 60 Hz, while the catalog states 127 / 490 GPM. Confirm against an approved curve before quotation.

Dimension drawing for MEUDY 100C47.5T 50 Hz configurationRepresentative catalog drawing · 100C47.5T · 50 Hz

Construction

Cast-iron body, ductile-iron inlet plate.

Discharge / flange plate
Cast iron / cast iron
Pump body / motor body
Cast iron / cast iron
Impeller
Cast iron / tungsten carbide
Inlet plate / seat
Ductile iron / steel
Bearings
Ball bearings
Mechanical seal
SiC-SiC / SiC-SiC

SOURCE & REVIEW

Evidence stays tied to this Type T entry.

01

Published source

MEUDY sewage pump catalog 2026.6.6, printed pages 67-69 with specifications, materials, 50/60 Hz curves and Y and Z dimensions.

02

Current catalog

Nine exact frequency, voltage, image and dimension assignments come from current English C(T) records.

03

Confirmation

Missing 60 Hz records, the 100C43.7T flow conflict, certification scope and North American suitability require confirmation.

C TYPE T FAQ

Selection questions answered from evidence.

Which models are in the C 2.2-7.5 kW 4P Type T range?

Published data groups 80C42.2T, 100C42.2T, 80C43.7T, 100C43.7T, 100C45.5T and 100C47.5T in this Type T entry.

Does every Type T four-pole model have both frequencies?

No. The current catalog has both frequencies for 100C42.2T, 80C43.7T and 100C43.7T. It currently lacks 60 Hz records for 80C42.2T, 100C45.5T and 100C47.5T.

Which Type T installation arrangements are documented?

Published data documents hard-pipe installation Y and auto-coupled installation Z. It does not show movable soft-pipe installation R for this entry.

Why is 100C43.7T maximum flow flagged?

Published data lists 550 GPM at 50 Hz and 528 GPM at 60 Hz. Current catalog records state 559 GPM and 490 GPM respectively, so an approved curve is required before quotation.

Is the regular C 2.2-7.5 kW 4P range included here?

No. Published data gives the regular four-pole C range and Type T separate product entries with different model codes, images and dimensions.

Continue from published data to a reviewed selection

Confirm frequency, flow and duty point.