C SERIES · TYPE T FOUR-POLE SEWAGE PUMP
C 2.2-7.5 kW 4P Type T sewage pump
One product family with six hydraulic models and nine current 50/60 Hz catalog configurations.
● Published pages 67-69 · 6 exact codes · 9 catalog configurations

Series Overview
Key specifications shared across the C 2.2-7.5 kW 4P Type T series.
Published data specifies IP68 protection, class F insulation, three-phase 380 V +/-10% at 50 Hz and 60 Hz, water temperature up to 40°C and pH 6-10. Current matching catalog records retain that phase and voltage, but three model-frequency records are missing.
Model Range
Compare hydraulic performance across all available power ratings.
Six published models, 50 Hz and 60 Hz side by side. Rated and maximum columns show flow / head in GPM / ft. Missing catalog frequencies do not remove published values.
| Model | Motor HP | Outlet mm | 50 Hz rated / max GPM / ft | 60 Hz rated / max GPM / ft | Passage mm | Cable mm² |
|---|---|---|---|---|---|---|
| 80C42.2T | 3.0 | 80 | 40 / 8 70 / 13 | 40 / 8 70 / 14 | 50 | 1.5 |
| 100C42.2T | 3.0 | 100 | 40 / 8 95 / 13 | 40 / 8 95 / 14 | 50 | 1.5 |
| 80C43.7T | 5.0 | 80 | 60 / 11 90 / 16 | 60 / 11 85 / 18 | 55 | 1.5 |
| 100C43.7T | 5.0 | 100 | 60 / 11 125 / 16 | 60 / 11 120 / 18 | 55 | 1.5 |
| 100C45.5T | 7.4 | 100 | 65 / 13 135 / 20 | 65 / 13 135 / 22 | 55 | 2.5 |
| 100C47.5T | 10.1 | 100 | 80 / 15 150 / 24 | 80 / 15 150 / 25 | 55 | 4.0 |
For each frequency column, the first line is rated flow / head and the second line is maximum flow / head.

80 MM OUTLET · 2.2-3.7 KW
80C42.2T / 80C43.7T
One distinct catalog image is shared by the listed model and frequency records.
100 MM OUTLET · 2.2-3.7 KW
100C42.2T / 100C43.7T
One distinct catalog image is shared by the listed model and frequency records.
100 MM OUTLET · 5.5-7.5 KW
100C45.5T / 100C47.5T
One distinct catalog image is shared by the listed model and frequency records.Configurations
Available 50 Hz / 60 Hz electrical configurations for each model.
Three 60 Hz records are missing, and one model has a material maximum-flow difference from published data.
| Exact code | Hz | Phase / V | Power HP | Outlet mm | Rated flow / head GPM / ft | Max flow / head GPM / ft | Drawing |
|---|---|---|---|---|---|---|---|
| 80C42.2T | 50 | 3 / 380 | 3.0 | 80 | 176.1 / 26.2 | 308.2 / 43.3 | View |
| 100C42.2T | 50 | 3 / 380 | 3.0 | 100 | 176.1 / 26.2 | 418.3 / 42.7 | View |
| 100C42.2T | 60 | 3 / 380 | 3.0 | 100 | 176.1 / 26.2 | 418.3 / 45.6 | View |
| 80C43.7T | 50 | 3 / 380 | 5.0 | 80 | 264.2 / 36.1 | 396.3 / 53.1 | View |
| 80C43.7T | 60 | 3 / 380 | 5.0 | 80 | 264.2 / 36.1 | 374.2 / 60.4 | View |
| 100C43.7T | 50 | 3 / 380 | 5.0 | 100 | 264.2 / 36.1 | 559.2 / 53.1 | View |
| 100C43.7T | 60 | 3 / 380 | 5.0 | 100 | 264.2 / 36.1 | 490.0 / 60.4 | View |
| 100C45.5T | 50 | 3 / 380 | 7.4 | 100 | 286.2 / 42.7 | 594.4 / 65.9 | View |
| 100C47.5T | 50 | 3 / 380 | 10.1 | 100 | 352.2 / 49.2 | 660.4 / 79.4 | View |
Current catalog gaps: 80C42.2T, 100C45.5T and 100C47.5T have no 60 Hz record. For 100C43.7T, published data lists 125 / 528 GPM maximum flow at 50 / 60 Hz, while the catalog states 127 / 490 GPM. Confirm against an approved curve before quotation.
Representative catalog drawing · 100C47.5T · 50 HzConstruction
Cast-iron body, ductile-iron inlet plate.
- Discharge / flange plate
- Cast iron / cast iron
- Pump body / motor body
- Cast iron / cast iron
- Impeller
- Cast iron / tungsten carbide
- Inlet plate / seat
- Ductile iron / steel
- Bearings
- Ball bearings
- Mechanical seal
- SiC-SiC / SiC-SiC
SOURCE & REVIEW
Evidence stays tied to this Type T entry.
Published source
MEUDY sewage pump catalog 2026.6.6, printed pages 67-69 with specifications, materials, 50/60 Hz curves and Y and Z dimensions.
Current catalog
Nine exact frequency, voltage, image and dimension assignments come from current English C(T) records.
Confirmation
Missing 60 Hz records, the 100C43.7T flow conflict, certification scope and North American suitability require confirmation.
C TYPE T FAQ
Selection questions answered from evidence.
Which models are in the C 2.2-7.5 kW 4P Type T range?
Published data groups 80C42.2T, 100C42.2T, 80C43.7T, 100C43.7T, 100C45.5T and 100C47.5T in this Type T entry.
Does every Type T four-pole model have both frequencies?
No. The current catalog has both frequencies for 100C42.2T, 80C43.7T and 100C43.7T. It currently lacks 60 Hz records for 80C42.2T, 100C45.5T and 100C47.5T.
Which Type T installation arrangements are documented?
Published data documents hard-pipe installation Y and auto-coupled installation Z. It does not show movable soft-pipe installation R for this entry.
Why is 100C43.7T maximum flow flagged?
Published data lists 550 GPM at 50 Hz and 528 GPM at 60 Hz. Current catalog records state 559 GPM and 490 GPM respectively, so an approved curve is required before quotation.
Is the regular C 2.2-7.5 kW 4P range included here?
No. Published data gives the regular four-pole C range and Type T separate product entries with different model codes, images and dimensions.
Continue from published data to a reviewed selection