KBZE SERIES · INTELLIGENT SUBMERSIBLE DRAINAGE PUMP
Automatic drainage.
Built-in protection.
A cast-iron top-discharge pump range with an integrated controller and adjustable water-level probe for automatic operation in civil engineering, mines, quarries, slurry service, sewage treatment and general drainage.
● 9 published models · 9 exact codes · 18 current records

POWER2.0-7.4 HP
MAX FLOW462.3 GPM
MAX HEAD124.7 ft
MAX DEPTH25 m
Series Overview
Key specifications shared across the KBZE series.
Published data describes a built-in intelligent controller and adjustable electric probe. It protects against reverse phase, open phase, impeller jam, overload, abnormal voltage and high temperature, and provides rapid operation assessment and malfunction diagnosis.
Model Range
Compare hydraulic performance across all available power ratings.
Printed pages 25-28 define KBZE separately from KBZ. Every model has a 50 Hz and 60 Hz performance rows, one dimensions row and two matching current catalog records.

CURRENT CATALOG IMAGE
KBZE21.5 · KBZE22.2
One content-distinct source asset.
CURRENT CATALOG IMAGE
KBZE23.7
One content-distinct source asset.
CURRENT CATALOG IMAGE
KBZE31.5 · KBZE32.2
One content-distinct source asset.
CURRENT CATALOG IMAGE
KBZE33.7
One content-distinct source asset.
CURRENT CATALOG IMAGE
KBZE35.5
One content-distinct source asset.
CURRENT CATALOG IMAGE
KBZE43.7
One content-distinct source asset.
CURRENT CATALOG IMAGE
KBZE45.5
One content-distinct source asset.| Model | Outlet mm | Power HP | Rated current 50 / 60 Hz A | 50 Hz rated · max GPM / ft | 60 Hz rated · max GPM / ft | Passage mm |
|---|---|---|---|---|---|---|
| KBZE21.5 | 50 | 2.0 | 3.5 / 3.5 | 66.0 / 49.2 · 118.9 / 72.2 | 66.0 / 54.1 · 118.9 / 75.5 | 8.5 |
| KBZE31.5 | 80 | 2.0 | 3.5 / 3.5 | 132.1 / 26.2 · 176.1 / 47.6 | 132.1 / 29.5 · 198.1 / 49.2 | 8.5 |
| KBZE22.2 | 50 | 3.0 | 5.0 / 5.1 | 79.3 / 65.6 · 145.3 / 85.3 | 79.3 / 65.6 · 136.5 / 91.9 | 8.5 |
| KBZE32.2 | 80 | 3.0 | 5.0 / 5.1 | 158.5 / 36.1 · 242.2 / 62.3 | 132.1 / 42.7 · 206.9 / 67.3 | 8.5 |
| KBZE23.7 | 50 | 5.0 | 7.7 / 8.0 | 52.8 / 98.4 · 145.3 / 111.5 | 52.8 / 98.4 · 220.1 / 108.3 | 8.5 |
| KBZE33.7 | 80 | 5.0 | 7.7 / 8.0 | 132.1 / 65.6 · 242.2 / 95.1 | 132.1 / 72.2 · 242.2 / 101.7 | 8.5 |
| KBZE43.7 | 100 | 5.0 | 7.7 / 8.0 | 264.2 / 37.7 · 396.3 / 60.7 | 264.2 / 37.7 · 422.7 / 60.7 | 8.5 |
| KBZE35.5 | 80 | 7.4 | 11.4 / 11.6 | 158.5 / 82.0 · 330.2 / 111.5 | 158.5 / 82.0 · 303.8 / 124.7 | 8.5 |
| KBZE45.5 | 100 | 7.4 | 11.4 / 11.6 | 264.2 / 52.5 · 462.3 / 75.5 | 264.2 / 52.5 · 449.1 / 80.1 | 8.5 |
Each frequency cell shows rated flow/head followed by maximum flow/head. Published values remain separate from decimal-resolved current records below.
| Model | Outlet d mm | A / A1 / B / D / H / W1 mm | N.W. / G.W. kg | Packing mm |
|---|---|---|---|---|
| KBZE21.5 | 50 | 240 / 196 / 623 / 216 / 577 / 120 | 41 / 45 | 695×265×275 |
| KBZE31.5 | 80 | 240 / 204 / 631 / 216 / 577 / 120 | 41 / 45 | 695×265×275 |
| KBZE22.2 | 50 | 240 / 196 / 623 / 216 / 577 / 120 | 44 / 48 | 695×265×275 |
| KBZE32.2 | 80 | 240 / 204 / 631 / 216 / 577 / 120 | 44 / 48 | 695×265×275 |
| KBZE23.7 | 50 | 293 / 234 / 708 / 252 / 708 / 150 | 71 / 76 | 790×320×305 |
| KBZE33.7 | 80 | 293 / 240 / 716 / 252 / 708 / 150 | 71 / 76 | 790×320×305 |
| KBZE43.7 | 100 | 299 / 249 / 729 / 252 / 708 / 150 | 72 / 77 | 790×320×305 |
| KBZE35.5 | 80 | 329 / 259 / 769 / 300 / 663 / 150 | 85.5 / 92.5 | 845×355×375 |
| KBZE45.5 | 100 | 329 / 268 / 782 / 300 / 663 / 150 | 86.5 / 93.5 | 845×355×375 |
Configurations
Available 50 Hz / 60 Hz electrical configurations for each model.
Every KBZE model has one three-phase 400 V 50 Hz record and one three-phase 380 V 60 Hz record. All current product images and drawing links remain attached to their exact codes.
| Exact code | Hz | Phase / V | Power HP | Rated flow / head GPM / ft | Max flow / head GPM / ft | Outlet / passage mm | N.W. kg | Cable m | Drawing |
|---|---|---|---|---|---|---|---|---|---|
| KBZE21.5 | 50 | 3 / 400 | 2.0 | 66.0 / 49.2 | 119.3 / 72.2 | 50 / 8.5 | 41 | 8 | View |
| KBZE21.5 | 60 | 3 / 380 | 2.0 | 66.0 / 54.1 | 119.8 / 75.8 | 50 / 8.5 | 41 | 8 | View |
| KBZE22.2 | 50 | 3 / 400 | 3.0 | 79.3 / 65.6 | 145.7 / 85.3 | 50 / 8.5 | 44 | 8 | View |
| KBZE22.2 | 60 | 3 / 380 | 3.0 | 79.3 / 65.6 | 137.8 / 91.9 | 50 / 8.5 | 44 | 8 | View |
| KBZE23.7 | 50 | 3 / 400 | 5.0 | 52.8 / 98.4 | 145.7 / 111.5 | 50 / 8.5 | 71 | 8 | View |
| KBZE23.7 | 60 | 3 / 380 | 5.0 | 52.8 / 98.4 | 218.4 / 108.6 | 50 / 8.5 | 71 | 8 | View |
| KBZE31.5 | 50 | 3 / 400 | 2.0 | 132.1 / 26.2 | 176.6 / 47.6 | 80 / 8.5 | 41 | 8 | View |
| KBZE31.5 | 60 | 3 / 380 | 2.0 | 132.1 / 29.5 | 198.6 / 49.5 | 80 / 8.5 | 41 | 8 | View |
| KBZE32.2 | 50 | 3 / 400 | 3.0 | 158.5 / 36.1 | 242.6 / 62.3 | 80 / 8.5 | 44 | 8 | View |
| KBZE32.2 | 60 | 3 / 380 | 3.0 | 132.1 / 42.7 | 211.8 / 67.6 | 80 / 8.5 | 44 | 8 | View |
| KBZE33.7 | 50 | 3 / 400 | 5.0 | 132.1 / 65.6 | 242.6 / 96.5 | 80 / 8.5 | 71 | 8 | View |
| KBZE33.7 | 60 | 3 / 380 | 5.0 | 132.1 / 72.2 | 246.1 / 101.4 | 80 / 8.5 | 71 | 8 | View |
| KBZE35.5 | 50 | 3 / 400 | 7.4 | 158.5 / 82.0 | 330.7 / 111.5 | 80 / 8.5 | 85.5 | 8 | View |
| KBZE35.5 | 60 | 3 / 380 | 7.4 | 158.5 / 82.0 | 301.6 / 124.7 | 80 / 8.5 | 85.5 | 8 | View |
| KBZE43.7 | 50 | 3 / 400 | 5.0 | 264.2 / 37.7 | 396.7 / 60.7 | 100 / 8.5 | 72 | 8 | View |
| KBZE43.7 | 60 | 3 / 380 | 5.0 | 264.2 / 37.7 | 427.1 / 60.7 | 100 / 8.5 | 72 | 8 | View |
| KBZE45.5 | 50 | 3 / 400 | 7.4 | 264.2 / 52.5 | 462.3 / 75.8 | 100 / 8.5 | 86.5 | 8 | View |
| KBZE45.5 | 60 | 3 / 380 | 7.4 | 264.2 / 52.5 | 458.3 / 80.4 | 100 / 8.5 | 86.5 | 8 | View |
Current records retain decimal endpoints such as 119.3/119.8 GPM for KBZE21.5 and 458.3 GPM / 80.4 ft for KBZE45.5 at 60 Hz, while performance tables show rounded values. Confirm the approved curve before quotation.
Construction & materials
Integrated controls above an abrasion-resistant wet end.
Published data separates seal construction by motor power: SiC-SiC / carbon-SiC below 2.2 kW, and SiC-SiC / SiC-SiC above 3.7 kW. Materials not printed in the table are not inferred.
- Discharge connection
- Cast iron
- Handle
- Rubber & steel
- Upper support / motor / pump body
- Cast iron
- Impeller
- High chrome alloy
- Inlet plate
- Ductile iron
- Strainer
- Steel
- Rotor shaft
- AISI 420 stainless steel
- Bearings
- Ball bearing
SOURCE & REVIEW
Evidence stays tied to KBZE.
Published source
English engineering-pump published printed pages 25-28 with automatic-control sequence, materials, dimensions, 50/60 Hz curves and nine performance rows.
Current catalog
Eighteen exact frequency records, seven content-distinct product images and nine dimension paths representing seven content-distinct drawings.
Confirmation
Certification scope, North American electrical suitability and final duty selection require written confirmation before quotation.
KBZE FAQ
Automatic control and source boundaries.
Is KBZE a separate published product entry from KBZ?
Yes. The published data Contents assigns KBZE its own pages 25-28, so this page is separate from the KBZ pages 21-24.
How does KBZE control water level?
An adjustable electric probe controls operation. Published data states that the pump stops within 60 seconds after the level falls below the probe and starts again when water reaches it.
What built-in protection does KBZE provide?
Published data lists reverse-phase, open-phase, impeller-jam, overload, abnormal-voltage and high-temperature responses, including automatic recovery where specified.
Are both published frequencies represented in the current catalog?
Yes. All nine exact KBZE codes have one current 50 Hz record and one current 60 Hz record.
Why do some current maximum values differ slightly from published data?
The current catalog retains decimal-resolved endpoints while published data tables use rounded values. Both sources are shown separately and should be confirmed against the approved curve before quotation.
Need automatic heavy-duty drainage?