KA · LARGE FLOW SEAWATER PUMP

KA large-flow seawater pump.
Low head, high capacity.

Published data describes an axial-flow or mixed-flow energy-saving pump with low head and large flow. Bottom intake discharges through a side motor channel for cooling, with AISI 444 impeller and AISI 316L motor casing for seawater service.

7 performance rows · 8 current model codes · 15 current records

MEUDY KA4.75 large flow seawater pump current catalog image

POWER1.0-20.1 HP

MAX FLOW2905.9 GPM

RATED HEADup to 19.7 ft

SUPPLY1φ / 3φ

Series Overview

Key specifications shared across the KA series.

Published applications include aquaculture water supply and drainage of seawater or freshwater, agriculture irrigation, ponds and lakes, and landscaping. Axial-flow impellers are published for 0.75-7.5 kW and mixed-flow impellers above 11 kW.

AquacultureSeawater or freshwater supply and drainage
AgricultureWater supply, drainage and irrigation
Ponds and landscapingLake and landscape circulation

Model Range

Compare hydraulic performance across all available power ratings.

Printed pages 68-71 define KA as Large flow seawater pump. KA is three phase and KAM is single phase. KA1215 is published as 60 Hz only.

Current KA catalog image used for KA4.75, KAM4.75

CURRENT CATALOG IMAGE

KA4.75 · KAM4.75

Shared representative asset for the listed codes; not claimed as unique photography per code.
Current KA catalog image used for KA4.75, KAM4.75

CURRENT CATALOG IMAGE

KA4.75 · KAM4.75

Shared representative asset for the listed codes; not claimed as unique photography per code.
Current KA catalog image used for KA61.5, KA62.2

CURRENT CATALOG IMAGE

KA61.5 · KA62.2

Shared representative asset for the listed codes; not claimed as unique photography per code.
Current KA catalog image used for KA61.5, KA62.2

CURRENT CATALOG IMAGE

KA61.5 · KA62.2

Shared representative asset for the listed codes; not claimed as unique photography per code.
Current KA catalog image used for KA85.5

CURRENT CATALOG IMAGE

KA85.5

Content-distinct product asset for this code.
Current KA catalog image used for KA85.5

CURRENT CATALOG IMAGE

KA85.5

Content-distinct product asset for this code.
Current KA catalog image used for KA107.5

CURRENT CATALOG IMAGE

KA107.5

Content-distinct product asset for this code.
Current KA catalog image used for KA107.5

CURRENT CATALOG IMAGE

KA107.5

Content-distinct product asset for this code.
Current KA catalog image used for KA1211

CURRENT CATALOG IMAGE

KA1211

Content-distinct product asset for this code.
Current KA catalog image used for KA1211, KA1215

CURRENT CATALOG IMAGE

KA1211 · KA1215

Shared representative asset for the listed codes; not claimed as unique photography per code.
ModelOutlet
mm
Power
HP
Current 1φ / 3φ
A
Rated flow 50 / 60 Hz
GPM
Rated head 50 / 60 Hz
ft
Max flow 50 / 60 Hz
GPM
Passage
mm
KA(M)4.751001.05.0 / 2.0184.9 / 184.99.8 / 9.8277.4 / 277.410
KA61.51502.0- / 3.7528.3 / 528.37.5 / 8.2713.3 / 660.420
KA62.21503.0- / 5.1528.3 / 528.39.8 / 11.5792.5 / 845.420
KA85.52007.4- / 11.71056.7 / 1188.813.1 / 14.81453.0 / 1585.022
KA107.525010.1- / 15.71585.0 / 1585.013.1 / 13.12113.4 / 1849.222
KA121130014.8- / 221981.3 / 1981.316.4 / 19.72377.6 / 2641.733
KA121530020.1- / 30.1Not listed / 2377.6Not listed / 19.7Not listed / 2905.933

Published performance table does not list a separate maximum-head column. KA1215 shows Not listed for 50 Hz cells because it is published as 60 Hz only.

Modeld / B / D / H / W1
mm
N.W. / G.W.
kg
Packing
mm
KA(M)4.75100 / 454 / 225 / 525 / 20025 / 27620×270×315
KA61.5150 / 602 / 285 / 672 / 30047 / 51750×320×345
KA62.2150 / 602 / 285 / 672 / 30050 / 54750×320×345
KA85.5200 / 757 / 340 / 877 / 400115 / 128945×395×465
KA107.5250 / 825 / 390 / 975 / 500145 / 1601065×435×505
KA1211315 / 848 / 445 / 1030 / 600186 / 2051105×495×565
KA1215315 / 878 / 445 / 1060 / 600195 / 2151105×495×565

Configurations

Available 50 Hz / 60 Hz electrical configurations for each model.

Current catalog lists both KA4.75 and KAM4.75 for the KA(M)4.75 published row. Values below remain current-catalog facts and do not overwrite the published table.

Exact codeHzPhase / VPower
HP
Rated flow / head
GPM / ft
Max flow / head
GPM / ft
Outlet / passage
mm
N.W.
kg
Drawing
KA4.75503 / 3801.0184.9 / 9.8282.2 / 22.0100 / 1025View drawing
KA4.75603 / 3801.0184.9 / 9.8278.3 / 26.9100 / 1025View drawing
KA61.5503 / 3802.0528.3 / 7.5713.3 / 19.7150 / 2047View drawing
KA61.5603 / 3802.0528.3 / 8.2658.7 / 24.3150 / 2047View drawing
KA62.2503 / 3803.0528.3 / 9.8792.5 / 21.7150 / 2050View drawing
KA62.2603 / 3803.0528.3 / 11.5844.5 / 26.9150 / 2050View drawing
KA85.5503 / 3807.41056.7 / 13.11466.2 / 35.8200 / 22115View drawing
KA85.5603 / 3807.41188.8 / 14.81608.4 / 42.0200 / 22115View drawing
KA107.5503 / 38010.11585.0 / 13.12201.4 / 42.3250 / 22145View drawing
KA107.5603 / 38010.11585.0 / 13.11946.5 / 48.9250 / 22145View drawing
KA1211503 / 38014.81981.3 / 16.42377.6 / 41.0320 / 33186View drawing
KA1211603 / 38014.81981.3 / 19.72777.3 / 42.7320 / 33186View drawing
KA1215603 / 38020.12377.6 / 19.73073.2 / 59.4320 / 33195View drawing
KAM4.75501 / 2201.0184.9 / 9.8283.1 / 23.0100 / 1025View drawing
KAM4.75601 / 1151.0184.9 / 9.8277.8 / 29.5100 / 1025View drawing

Current catalog differences: Several codes list maximum head even though the published table does not; KA1211 / KA1215 current outlet is listed as 320 mm while published dimensions use 300 mm / 315 (DN300); maxima such as KA85.5 and KA107.5 show decimal-resolved or different values versus published rounded capacity. Confirm the approved curve and connection before quotation.

SUMMARY CAPACITYUp to 2905.9 GPM
SUMMARY POWER1.0-20.1 HP
SUPPLY1φ 115 V (NA default · 60 Hz) / 3φ 380 V
INSULATIONF (0.75-2.2 kW) · H (5.5-15 kW)
PROTECTIONIP68
WATER / DEPTH / CABLE40 °C · 10 m · 6/8 m

Published data lists other voltages and optional cable length. Cable is published as 6 m at 0.75 kW and 8 m from 1.5-15 kW.

Construction

AISI 444 impeller. AISI 316L motor casing.

Printed pages 70-71 separate 0.75-2.2 kW and 5.5-15 kW material stacks. Both include an aluminum-alloy cathodic protection plate.

Impeller
AISI 444 SS
Motor casing / shaft
AISI 316L SS
Outer casing / strainer
AISI 304 SS
Discharge connection
PVC (cast iron optional on larger models)
Mechanical seal
Sic-Ceramic/Carbon-Ceramic (0.75 kW) · Sic-Sic/Carbon-Ceramic (1.5-2.2 kW) · Sic-Sic/Sic-Sic (5.5-15 kW)
Cathodic protection plate
Aluminum alloy

SOURCE & REVIEW

Evidence stays tied to KA.

01

Published source

Published data printed pages 68-71 with seawater narrative, materials for both power bands, dimensions, curves and seven performance rows.

02

Current catalog

Fifteen exact frequency records for eight codes including KA4.75 and KAM4.75.

03

Confirmation

Outlet DN differences, current maximum-head fields and decimal-resolved maxima require confirmation.

KA FAQ

Model boundaries and quotation checks.

Is KA a separate Contents item?

Yes. KA is an independent published data Contents item on printed pages 68-71, titled Large flow seawater pump KA.

How are KA and KAM counted?

Published footnotes define KA as three phase and KAM as single phase. The published performance table shows seven hydraulic rows, with KA(M)4.75 covering both single-phase and three-phase 0.75 kW codes. KA1215 is published as 60 Hz only.

Which current records match?

The current catalog has fifteen frequency records covering KA4.75, KAM4.75, KA61.5, KA62.2, KA85.5, KA107.5, KA1211 and KA1215. KA1215 currently lists 60 Hz only, matching the published note.

What materials does published data list for seawater service?

Printed pages 70-71 list AISI 444 SS impeller, AISI 316L SS motor casing and rotor shaft, AISI 304 SS outer casing and strainer, PVC discharge connection and an aluminum-alloy cathodic protection plate.

Does the published KA table list maximum head?

No. The published performance table lists rated head and maximum capacity, not a separate maximum-head column. Current catalog records may list maximum head as a separate current-catalog fact.

Need low-head large-flow seawater or freshwater transfer?

Review KA performance rows and the current catalog codes.