FSM SERIES · SUBMERSIBLE DRAINAGE PUMP

Drain muddy water.
Keep flow moving.

A semi-vortex drainage platform with a shaft-mounted agitator for civil engineering, construction sites, basements, utility pits, rainwater, muddy water and higher-viscosity liquids.

● 0.4-1.5 kW · 10 models · 20 configurations

MEUDY FSM submersible drainage pump

POWER0.5-2.0 HP

MAX FLOW145.3 GPM

MAX HEAD78.7 ft

PASSAGE6 mm

Series Overview

Key specifications shared across the FSM series.

The semi-vortex impeller minimizes clogging while the shaft-mounted agitator reduces air lock and keeps settled solids moving toward the inlet. Published data specifies water up to 40°C, pH 6.5-8.5, IP68 protection, class F insulation, an 8 m cable and immersion up to 10 m.

Construction drainageCivil works, utility pits and basements
Muddy waterRainwater and water carrying settled solids
Agitated intakeBuilt-in agitator supports difficult drainage duties

Model Range

Compare hydraulic performance across all available power ratings.

Published data keeps FS, FSM and float-switch suffixes inside one FSM performance block. FSME is a separate Contents item and is excluded from this page even though the catalog shares its series field.

MEUDY FSM catalog image assigned to FSM2.4 / FS2.4

CURRENT CATALOG IMAGE

FSM2.4 / FS2.4

One of ten content-distinct images assigned to current FSM records.
MEUDY FSM catalog image assigned to FSM2.4F

CURRENT CATALOG IMAGE

FSM2.4F

One of ten content-distinct images assigned to current FSM records.
MEUDY FSM catalog image assigned to FSM2.75 / FS2.75

CURRENT CATALOG IMAGE

FSM2.75 / FS2.75

One of ten content-distinct images assigned to current FSM records.
MEUDY FSM catalog image assigned to FSM2.75F

CURRENT CATALOG IMAGE

FSM2.75F

One of ten content-distinct images assigned to current FSM records.
MEUDY FSM catalog image assigned to FSM3.75 / FS3.75

CURRENT CATALOG IMAGE

FSM3.75 / FS3.75

One of ten content-distinct images assigned to current FSM records.
MEUDY FSM catalog image assigned to FSM3.75F

CURRENT CATALOG IMAGE

FSM3.75F

One of ten content-distinct images assigned to current FSM records.
MEUDY FSM catalog image assigned to FSM21.1 / FSM21.5

CURRENT CATALOG IMAGE

FSM21.1 / FSM21.5

One of ten content-distinct images assigned to current FSM records.
MEUDY FSM catalog image assigned to FSM21.1F / FSM21.5F

CURRENT CATALOG IMAGE

FSM21.1F / FSM21.5F

One of ten content-distinct images assigned to current FSM records.
MEUDY FSM catalog image assigned to FSM31.1 / FSM31.5

CURRENT CATALOG IMAGE

FSM31.1 / FSM31.5

One of ten content-distinct images assigned to current FSM records.
MEUDY FSM catalog image assigned to FSM31.1F / FSM31.5F

CURRENT CATALOG IMAGE

FSM31.1F / FSM31.5F

One of ten content-distinct images assigned to current FSM records.
Performance rowPower
HP
Outlet
mm
50 Hz rated / max
GPM / ft
60 Hz rated / max
GPM / ft
Passage
mm
N.W.
kg
FS(M)2.4(F)0.55030.8 / 26.2
55.5 / 39.4
30.8 / 26.2
55.5 / 39.4
613.5
FS(M)2.75(F)1.05044.0 / 36.1
70.4 / 59.1
44.0 / 36.1
66.0 / 62.3
616.5
FS(M)3.75(F)1.08052.8 / 32.8
79.3 / 55.8
52.8 / 32.8
79.3 / 59.1
618
FS(M)21.1(F)1.55052.8 / 45.9
110.1 / 62.3
52.8 / 45.9
110.1 / 62.3
618.5
FS(M)31.1(F)1.58052.8 / 45.9
132.1 / 62.3
52.8 / 45.9
132.1 / 62.3
618.5
FS(M)21.5(F)2.05066.0 / 52.5
123.3 / 72.2
66.0 / 55.8
123.3 / 78.7
620.5
FS(M)31.5(F)2.08066.0 / 52.5
145.3 / 72.2
66.0 / 55.8
145.3 / 78.7
620.5

Published slash values are separated into 50 Hz and 60 Hz columns here. Current catalog decimals remain separate below.

Configurations

Available 50 Hz / 60 Hz electrical configurations for each model.

Counted page codes are the FS/FSM base forms (10 codes × both frequencies = 20 records). Single-phase models can be configured with a float switch; float codes (FSM2.4F, FSM2.75F, FSM3.75F, FSM21.1F, FSM31.1F, FSM21.5F, FSM31.5F) are not separate table rows. The table preserves exact codes, electrical supply, duty points, maximum points, outlets, cable length and model-specific drawing links in server-rendered HTML.

Exact codeHzPhase / VPower
HP
Rated flow / head
GPM / ft
Max flow / head
GPM / ft
Outlet / passage
mm
Cable
m
Drawing
FS2.4503 / 3800.530.8 / 26.255.9 / 39.450 / 68View
FS2.4603 / 2080.530.8 / 26.256.4 / 39.450 / 68View
FSM2.4501 / 2200.530.8 / 26.255.9 / 39.450 / 68View
FSM2.4601 / 1150.530.8 / 26.255.9 / 39.450 / 68View
FS2.75503 / 3801.044.0 / 36.170.4 / 59.150 / 68View
FS2.75603 / 3801.044.0 / 36.166.5 / 59.150 / 68View
FSM2.75501 / 2201.044.0 / 36.170.9 / 59.150 / 68View
FSM2.75601 / 1151.044.0 / 36.165.6 / 62.050 / 68View
FS3.75503 / 3801.052.8 / 32.879.3 / 55.880 / 68View
FS3.75603 / 3801.052.8 / 32.878.8 / 55.880 / 68View
FSM3.75501 / 2201.052.8 / 32.879.3 / 55.880 / 68View
FSM3.75601 / 1151.052.8 / 32.879.3 / 58.480 / 68View
FSM21.1501 / 2201.552.8 / 45.9110.5 / 62.350 / 68View
FSM21.1601 / 1151.552.8 / 45.9110.1 / 62.350 / 68View
FSM31.1501 / 2201.552.8 / 45.9132.1 / 62.380 / 68View
FSM31.1601 / 1151.552.8 / 45.9130.8 / 62.380 / 68View
FSM21.5501 / 2202.066.0 / 52.5122.8 / 72.250 / 68View
FSM21.5601 / 1152.066.0 / 55.8123.7 / 78.750 / 68View
FSM31.5501 / 2202.066.0 / 52.5144.9 / 72.280 / 68View
FSM31.5601 / 1152.066.0 / 55.8145.3 / 78.780 / 68View

Published data rounds family maximum points such as 55.5 GPM, 70.4/66.0 GPM and 123.3/145.3 GPM. Current catalog records retain values including 55.9, 70.9, 65.6, 122.8, 123.7, 144.9 and 145.3 GPM. Confirm the approved frequency curve before quotation.

LIQUID TEMPERATUREUp to 40°C
pH RANGE6.5-8.5
PROTECTIONIP68
IMMERSION DEPTHUp to 32.8 ft
CABLE8 m
SUPPLY1φ 115 V (NA default · 60 Hz) / 3φ as published
OUTLETS50 / 80 mm

Construction & materials

Semi-vortex hydraulics with an integral agitator.

The material stack follows the FSM published construction page. Exact supplied configuration remains subject to quotation review.

Pump body
Cast iron
Impeller
Ductile iron
Agitator
Stainless steel
Shaft / sleeve
AISI 420 stainless steel
Mechanical seal
Ceramic-SiC / carbon-ceramic
Cable
H07RN-F

FSM FAQ

Series and configuration boundaries.

Why are the FS and FSM configurations on one page?

Published data defines one FSM series block with seven hydraulic rows. FS identifies three phase, FSM single phase, and an F suffix a single-phase float-switch configuration.

Why is FSME not included on this page?

Published data Contents page lists FSME as a separate intelligent drainage-pump series on pages 05-06. Although the current catalog stores FSME under the FSM series field, those records are deliberately excluded here.

How many current FSM configurations are published?

After excluding FSME, counted page codes are the FS/FSM base forms (10 codes, 20 frequency records). Matching F float-switch codes remain outside that count.

Are three-phase FS versions available at every power?

Published data nomenclature allows FS versions, but the current English catalog publishes three-phase FS records only for the 0.4 kW and 0.75 kW hydraulic rows. Confirm availability before quotation.

Why do some maximum points contain decimals?

Published data table uses rounded family values while current records preserve model- and frequency-specific decimals. Keep the chosen frequency curve authoritative for selection and quotation.

Have a required flow and head?

Move from the FSM family to a reviewed configuration.