Products/Sewage/U 5.5-11 kW 4P

U SERIES · FOUR-POLE SUBMERSIBLE SEWAGE PUMP

U 5.5-11 kW 4P sewage pump range

One product family with five hydraulic models and nine current 50/60 Hz catalog records.

Published pages 53-56 · 5 exact codes · 9 catalog records

POWER7.4-14.8HPOUTLET80-100mmMAX FLOW836.6GPMMAX HEAD59.1ft
MEUDY U 100U411 four-pole sewage pump
Catalog image for 100U411 · 50/60 Hz image pair is byte-identical

Series Overview

Key specifications shared across the U 5.5-11 kW series.

R / Y / ZThree installations
7.4-10.1 HPBuilt-in motor protection
8 mCable length
20 mMaximum immersion depth

Published data specifies IP68 protection, class F insulation, three-phase 380 V supply at 50 Hz and 60 Hz, water temperature up to 40°C and pH 6-10. Built-in protection is stated only for 5.5-7.5 kW.

Model Range

Compare hydraulic performance across all available power ratings.

Five published models, 80 mm or 100 mm outlet. Rated and maximum columns show flow / head in GPM / ft. Separate 50 Hz and 60 Hz curves are provided.

ModelMotor
HP
Outlet
mm
Rated flow / head
GPM / ft
Max flow / head
GPM / ft
Passage
mm
Cable
mm²
80U45.57.480264.2 / 39.4418.3 / 49.2802.5
100U45.57.4100352.2 / 29.5594.4 / 45.91002.5
80U47.510.180352.2 / 45.9484.3 / 55.8804.0
100U47.510.1100484.3 / 32.8726.5 / 49.21004.0
100U41114.8100484.3 / 42.7836.6 / 59.11004.0

Published data provides the outlet sizes above. Current 50 Hz catalog outlet fields remain empty and are shown as dashes below.

MEUDY U 80 mm outlet catalog product image

80 MM OUTLET

80U45.5 / 80U47.5

Six catalog image paths resolve to three byte-identical frequency pairs; each visual is shown once.
MEUDY U 100 mm outlet · 5.5-7.5 kW catalog product image

100 MM OUTLET · 5.5-7.5 KW

100U45.5 / 100U47.5

Six catalog image paths resolve to three byte-identical frequency pairs; each visual is shown once.
MEUDY U 100 mm outlet · 11 kW catalog product image

100 MM OUTLET · 11 KW

100U411

Six catalog image paths resolve to three byte-identical frequency pairs; each visual is shown once.

Configurations

Available 50 Hz / 60 Hz electrical configurations for each model.

100U45.5 lacks 60 Hz, all 50 Hz outlet fields are empty, and one 60 Hz voltage conflicts with published data.

Exact codeHzPhase / VPower
HP
Outlet
mm
Rated flow / head
GPM / ft
Max flow / head
GPM / ft
Drawing
80U45.5503 / 3807.4-264.2 / 39.4418.3 / 49.9View
80U45.5603 / 3807.480264.2 / 39.4409.0 / 49.2View
80U47.5503 / 38010.1-352.2 / 45.9446.0 / 56.1View
80U47.5603 / 38010.180352.2 / 45.9493.6 / 55.4View
100U45.5503 / 3807.4-352.2 / 29.5587.3 / 45.6View
100U47.5503 / 38010.1-484.3 / 32.8726.5 / 50.2View
100U47.5603 / 38010.1100484.3 / 32.8727.8 / 49.2View
100U411503 / 38014.8-484.3 / 42.7836.6 / 59.1View
100U411603 / 22014.8100484.3 / 42.7803.5 / 59.1View

Current catalog conflicts: 100U45.5 has no 60 Hz record; all five 50 Hz records have no outlet value; and 100U411 at 60 Hz states 220 V while published data specifies three-phase 380 V +/-10%. Confirm before quotation.

Dimension drawing for MEUDY 100U411 50 Hz configurationRepresentative catalog drawing · 100U411 · 50 Hz

Construction

Cast-iron body, ductile-iron impeller.

Discharge / flange plate
Cast iron / cast iron
Pump body / motor body
Cast iron / cast iron
Impeller
Ductile iron
Rotor shaft
Stainless steel
Bearings
Ball bearings
Mechanical seal
SiC-SiC

SOURCE & REVIEW

Evidence stays tied to this U entry.

01

Published source

MEUDY sewage pump catalog 2026.6.6, printed pages 53-56 with specifications, materials, curves and R, Y and Z dimensions.

02

Current catalog

Nine exact frequency, voltage, image and dimension assignments come from current English U records.

03

Confirmation

The missing frequency, empty outlets, 60 Hz voltage conflict, certification scope and North American suitability require confirmation.

U SERIES FAQ

Selection questions answered from evidence.

Which models are in the U 5.5-11 kW 4P range?

Published data groups 80U45.5, 100U45.5, 80U47.5, 100U47.5 and 100U411 in one 4-pole entry with 80 mm or 100 mm outlets.

Does every model have 50 Hz and 60 Hz catalog records?

No. The current catalog contains nine records. Every model except 100U45.5 has both frequencies; 100U45.5 currently has only a 50 Hz record.

Which motors have built-in protection?

Published data specifically states built-in motor protection for 5.5-7.5 kW. It does not extend that statement to the 11 kW model.

Why is the 100U411 60 Hz voltage flagged?

Published data specifies three-phase 380 V +/-10% at 50 Hz and 60 Hz, while the current 100U411 60 Hz catalog record states 220 V. Written confirmation is required.

Why do the 50 Hz outlet cells show a dash?

All five 50 Hz catalog records leave outlet diameter empty. Published data states 80 mm or 100 mm, but this page preserves raw catalog fields in the configuration table.

Continue from published data to a reviewed selection

Confirm frequency, voltage, outlet and duty point.