QXN · SUBMERSIBLE PUMP

QXN multi-stage submersible.
Wells, industry, irrigation.

Published data describes an internal-cooled multi-stage pump with the hydraulic part under the motor, double shaft seals with an oil chamber, and motors from 2.2 to 75 kW for mining, industrial, well and irrigation duties.

31 published 50 Hz rows · 16 published 60 Hz rows · 37 current codes · 40 current records

MEUDY QXN10/2-2.2 submersible pump current catalog image

POWER3.0-100.6 HP

MAX FLOW836.6 GPM

MAX HEADup to 673.2 ft

SUPPLY

Series Overview

Key specifications shared across the QXN series.

Published applications include mining, building, factory and industrial duties, water supply from wells, tanks or reservoirs, and garden or agricultural irrigation. These are published statements, not external verification.

Mining and industryBuilding, factory and industrial pumping
Wells and reservoirsWater supply from wells, tanks or reservoirs
IrrigationGarden use and agricultural irrigation

Model Range

Compare hydraulic performance across all available power ratings.

Printed pages 78-83 define QXN as Submersible pump. Model nomenclature encodes rated capacity, impeller stages and motor power.

Current QXN catalog image used for QXN10/2-2.2

CURRENT CATALOG IMAGE

QXN10/2-2.2

Content-distinct product asset for this code.
Current QXN catalog image used for QXN10/2-2.2

CURRENT CATALOG IMAGE

QXN10/2-2.2

Content-distinct product asset for this code.
Current QXN catalog image used for QXN10/3-3

CURRENT CATALOG IMAGE

QXN10/3-3

Content-distinct product asset for this code.
Current QXN catalog image used for QXN12.5/3-4

CURRENT CATALOG IMAGE

QXN12.5/3-4

Content-distinct product asset for this code.
Current QXN catalog image used for QXN15/3-5.5

CURRENT CATALOG IMAGE

QXN15/3-5.5

Content-distinct product asset for this code.
Current QXN catalog image used for QXN20/2-11

CURRENT CATALOG IMAGE

QXN20/2-11

Content-distinct product asset for this code.
Current QXN catalog image used for QXN20/3-11

CURRENT CATALOG IMAGE

QXN20/3-11

Content-distinct product asset for this code.
Current QXN catalog image used for QXN20/3-15

CURRENT CATALOG IMAGE

QXN20/3-15

Content-distinct product asset for this code.
Current QXN catalog image used for QXN20/4-15

CURRENT CATALOG IMAGE

QXN20/4-15

Content-distinct product asset for this code.
Current QXN catalog image used for QXN20/4-22

CURRENT CATALOG IMAGE

QXN20/4-22

Content-distinct product asset for this code.
Current QXN catalog image used for QXN20/5-18.5

CURRENT CATALOG IMAGE

QXN20/5-18.5

Content-distinct product asset for this code.
Current QXN catalog image used for QXN20/6-22

CURRENT CATALOG IMAGE

QXN20/6-22

Content-distinct product asset for this code.

Gallery shows the first twelve content-distinct current catalog images. All 38 distinct assets remain linked from the current-records drawings and JSON-LD image list.

Model Range

Compare hydraulic performance across all available power ratings.

Printed pages 80-81. Values below are evidence-backed published hydraulic facts; current catalog records stay in the next section.

ModelOutlet
mm
Power
HP
Current
A
Rated flow / head
GPM / ft
Max flow / head
GPM / ft
Passage
mm
QXN10/2-2.2503.05.444.0 / 111.5123.3 / 126.36
QXN25/1-2.2653.05.4110.1 / 55.8162.9 / 74.86
QXN10/3-3504.07.244.0 / 147.6123.3 / 166.76
QXN25/2-3654.07.2110.1 / 82.0162.9 / 110.96
QXN12.5/3-4505.48.855.0 / 164.0132.1 / 187.36
QXN25/2-4655.48.8110.1 / 98.4176.1 / 142.76
QXN15/3-5.5507.411.766.0 / 196.8140.9 / 223.16
QXN25/3-5.5657.411.7110.1 / 164.0176.1 / 209.36
QXN25/4-7.56510.115.7110.1 / 196.8184.9 / 275.36
QXN25/5-9.26512.319.1110.1 / 246.1193.7 / 342.86
QXN20/3-115014.82288.1 / 324.8220.1 / 347.86
QXN40/2-118014.822176.1 / 183.7396.3 / 209.68
QXN20/4-155020.13188.1 / 426.5220.1 / 465.26
QXN40/3-158020.131176.1 / 262.5396.3 / 296.38
QXN60/2-1510020.131264.2 / 164.0396.3 / 240.810
QXN100/2-1515020.131440.3 / 108.3616.4 / 196.210
QXN20/5-18.55025.537.288.1 / 524.9220.1 / 582.76
QXN40/3-18.58025.537.2176.1 / 328.1396.3 / 353.78
QXN60/2-18.510025.537.2264.2 / 196.8396.3 / 266.410
QXN100/2-18.515025.537.2440.3 / 144.4625.2 / 215.910
QXN20/6-225029.54588.1 / 590.5220.1 / 673.26
QXN40/4-228029.545176.1 / 377.3396.3 / 418.08
QXN40/4-258033.551176.1 / 426.5396.3 / 471.58
QXN60/3-2510033.551264.2 / 295.3396.3 / 405.210
QXN100/3-2515033.551440.3 / 180.4625.2 / 311.010
QXN40/5-308040.260.2176.1 / 49.2396.3 / 555.88
QXN100/3-3015040.260.2440.3 / 216.5625.2 / 335.010
QXN100/2-3715049.668440.3 / 246.1792.5 / 310.015
QXN100/2-4515060.382440.3 / 295.3792.5 / 353.015
QXN100/2-5515073.8100440.3 / 328.1836.6 / 379.915
QXN100/3-75150100.6134440.3 / 475.7834.3 / 541.315

Model Range

Compare hydraulic performance across all available power ratings.

Printed page 82. Codes without a current catalog match stay published-only and are marked below.

ModelOutlet
mm
Power
HP
Current
A
Rated flow / head
GPM / ft
Max flow / head
GPM / ft
Passage
mm
Current catalog
QXN10/2-2.2503.05.444.0 / 111.5132.1 / 127.36Listed
QXN25/1-2.2653.05.4110.1 / 55.8154.1 / 67.66Listed
QXN10/2-3504.07.244.0 / 147.6132.1 / 154.26Published only
QXN12.5/2-4505.48.855.0 / 164.0154.1 / 173.96Published only
QXN25/2-4655.48.8110.1 / 98.4176.1 / 140.16Listed
QXN15/2-5.5507.411.766.0 / 187.0162.9 / 193.66Published only
QXN25/2-5.5657.411.7110.1 / 147.6198.1 / 175.56Listed
QXN25/3-7.56510.115.7110.1 / 196.8198.1 / 251.66Listed
QXN25/3-9.26512.319.1110.1 / 246.1198.1 / 316.66Listed
QXN20/2-115014.82288.1 / 278.9220.1 / 290.76Listed
QXN40/2-118014.822176.1 / 180.4405.1 / 206.78Listed
QXN20/3-155020.13188.1 / 377.3220.1 / 430.46Listed
QXN40/2-158020.131176.1 / 246.1418.3 / 272.38Published only
QXN40/2-18.58024.837.2176.1 / 278.9431.5 / 315.08Published only
QXN20/4-225029.54588.1 / 557.7220.1 / 595.16Listed
QXN40/3-228029.545176.1 / 360.9440.3 / 403.58Published only

Published-only 60 Hz codes: QXN10/2-3, QXN12.5/2-4, QXN15/2-5.5, QXN40/2-15, QXN40/2-18.5, QXN40/3-22. Do not invent current catalog records for those codes.

Configurations

Available 50 Hz / 60 Hz electrical configurations for each model.

Current catalog values below remain separate from the published tables and do not overwrite published hydraulic rows.

Exact codeHzPhase / VPower
HP
Rated flow / head
GPM / ft
Max flow / head
GPM / ft
Outlet / passage
mm
N.W.
kg
Drawing
QXN10/2-2.2503 / 3803.044.0 / 111.5123.3 / 126.350 / 653View drawing
QXN10/2-2.2603 / 3803.044.0 / 111.5132.1 / 127.350 / 653View drawing
QXN10/3-3503 / 3804.044.0 / 147.6123.3 / 166.750 / 662View drawing
QXN12.5/3-4503 / 3805.455.0 / 164.0132.1 / 187.350 / 667View drawing
QXN15/3-5.5503 / 3807.466.0 / 196.8140.9 / 223.150 / 675View drawing
QXN20/2-11603 / 38014.888.1 / 278.9220.1 / 290.750 / 6164View drawing
QXN20/3-11503 / 38014.888.1 / 324.8220.1 / 347.850 / 6178View drawing
QXN20/3-15603 / 38020.188.1 / 377.3220.1 / 430.450 / 6196View drawing
QXN20/4-15503 / 38020.188.1 / 426.5220.1 / 465.250 / 6210View drawing
QXN20/4-22603 / 44029.588.1 / 557.7220.1 / 595.150 / 6240View drawing
QXN20/5-18.5503 / 38025.588.1 / 524.9220.1 / 582.750 / 6235View drawing
QXN20/6-22503 / 38029.588.1 / 590.5220.1 / 673.250 / 6268View drawing
QXN25/1-2.2503 / 3803.0110.1 / 55.8162.9 / 74.865 / 647View drawing
QXN25/1-2.2603 / 3803.0110.1 / 55.8154.1 / 67.665 / 647View drawing
QXN25/2-3503 / 3804.0110.1 / 82.0162.9 / 110.965 / 657View drawing
QXN25/2-4503 / 3805.4110.1 / 98.4176.1 / 142.765 / 664View drawing
QXN25/2-4603 / 3805.4110.1 / 98.4176.1 / 140.165 / 664View drawing
QXN25/2-5.5603 / 3807.4110.1 / 147.6198.1 / 175.565 / 672View drawing
QXN25/3-5.5503 / 3807.4110.1 / 164.0176.1 / 209.365 / 678View drawing
QXN25/3-7.5603 / 38010.1110.1 / 196.8198.1 / 251.665 / 687View drawing
QXN25/3-9.2603 / 22012.3110.1 / 246.1198.1 / 316.665 / 694View drawing
QXN25/4-7.5503 / 38010.1110.1 / 196.8184.9 / 275.365 / 692View drawing
QXN25/5-9.2503 / 38012.3110.1 / 246.1193.7 / 342.865 / 6106View drawing
QXN40/2-11503 / 38014.8176.1 / 183.7396.3 / 209.680 / 8176View drawing
QXN40/3-15503 / 38020.1176.1 / 262.5396.3 / 296.380 / 8206View drawing
QXN40/3-18.5503 / 38025.5176.1 / 328.1396.3 / 353.780 / 8225View drawing
QXN40/4-22503 / 38029.5176.1 / 377.3396.3 / 418.080 / 8227View drawing
QXN40/4-25503 / 38033.5176.1 / 426.5396.3 / 471.580 / 8269View drawing
QXN40/5-30503 / 38040.2176.1 / 49.2396.3 / 555.880 / 8310View drawing
QXN60/2-15503 / 38020.1264.2 / 164.0396.3 / 240.8100 / 10189View drawing
QXN60/2-18.5503 / 38025.5264.2 / 196.8396.3 / 266.4100 / 10204View drawing
QXN60/3-25503 / 38033.5264.2 / 295.3396.3 / 405.2100 / 10263View drawing
QXN100/2-15503 / 38020.1440.3 / 108.3616.4 / 196.2150 / 10199View drawing
QXN100/2-18.5503 / 38025.5440.3 / 144.4625.2 / 215.9150 / 10217View drawing
QXN100/2-37503 / 38049.6440.3 / 246.1792.5 / 310.0150 / 15390View drawing
QXN100/2-45503 / 38060.3440.3 / 295.3792.5 / 353.0150 / 15430View drawing
QXN100/2-55503 / 38073.8440.3 / 328.1836.6 / 379.9150 / 15515View drawing
QXN100/3-25503 / 38033.5440.3 / 180.4625.2 / 311.0150 / 10260View drawing
QXN100/3-30503 / 38040.2440.3 / 216.5625.2 / 335.0150 / 10281View drawing
QXN100/3-75503 / 380100.6440.3 / 475.7834.3 / 541.3150 / 15617View drawing

Current catalog differences: Several codes list decimal-resolved maxima versus published rounded values. Confirm the approved curve and stage count before quotation.

SUMMARY CAPACITYUp to 836.6 GPM
SUMMARY POWER3.0-100.6 HP
SUPPLY3φ 380 V
INSULATIONB (≤30 kW) · F (>37 kW)
PROTECTIONIP68
WATER / DEPTH / CABLE40 °C · 20 m · 15 m

Published data lists other voltages and optional cable length. Single-phase 115 V is not a published QXN supply option.

Construction

Double shaft seals. Oil chamber cooling path.

Printed pages 78-79 place the hydraulic part under the motor so pumped water cools the motor when the set is only partially immersed.

Pump casing / impeller / diffuser
Cast iron
Outer casing
Stainless steel (<30 kW)
Shaft
Stainless steel
Mechanical seal
Sic-Sic
Seat / strainer
Cast iron / steel
Seal arrangement
Double shaft seals with oil chamber

SOURCE & REVIEW

Evidence stays tied to QXN.

01

Published source

Published data printed pages 78-83 with nomenclature, materials, outlet diagrams, separate 50/60 Hz tables, curves and dimensions.

02

Current catalog

Forty exact frequency records for thirty-seven codes. Six published 60 Hz codes currently lack catalog records.

03

Confirmation

Stage-count differences between 50/60 Hz naming, published-only 60 Hz codes and decimal-resolved maxima require confirmation.

QXN FAQ

Model boundaries and quotation checks.

Is QXN a separate Contents item?

Yes. QXN is an independent published data Contents item on printed pages 78-83, titled Submersible pump QXN.

Why are 50 Hz and 60 Hz model codes different?

Published performance tables list stage-count codes separately by frequency. Some 60 Hz rows use different impeller-stage numbering than the matching 50 Hz family, so both tables remain visible.

Which published 60 Hz codes lack current catalog records?

Printed 60 Hz rows without a current catalog match are QXN10/2-3, QXN12.5/2-4, QXN15/2-5.5, QXN40/2-15, QXN40/2-18.5, QXN40/3-22. Those hydraulic rows stay published-only and are not invented as current records.

How many current catalog records match?

The current catalog has forty frequency records covering thirty-seven exact codes that appear in the published 50 Hz or 60 Hz tables.

What construction does published data emphasize?

Printed pages 78-79 state the hydraulic part sits under the motor for water cooling when only partially immersed, with double shaft seals and an interposed oil chamber. Materials include cast-iron wet-end parts, stainless outer casing below 30 kW and Sic-Sic mechanical seal.

Need multi-stage well or industrial transfer?

Review QXN published tables and the current catalog codes.