Published data describes NTZ as a submersible slurry pump with a 4-pole motor for increased lifetime and greater convenience. A high-chrome alloy impeller combined with an agitator is designed for heavy slurry, and a cooling water jacket allows low-water operation for an extended period without fear of overheating.
● 6 performance rows · 6 current model codes · 11 current records

POWER3.0-14.8 HP
MAX FLOW1083.1 GPM
MAX HEAD88.6 ft
SUPPLY3φ 380 V ±10%
Series Overview
Key specifications shared across the NTZ series.
Published data states that the high-chrome impeller and agitator are designed for heavy slurry, and that the cooling water jacket supports extended low-water operation. Applications include civil engineering, mines and quarries, sewage treatment plants and general pumping of sludge, mud and bentonite. These are published statements, not external verification.
Model Range
Compare hydraulic performance across all available power ratings.
Printed pages 47-49 define NTZ as SUBMERSIBLE SLURRY PUMP. The performance and dimension rows below are published facts and stay separate from the eleven current catalog records.

CURRENT CATALOG IMAGE
NTZ32.2 · NTZ33.7
Shared representative asset for the listed codes; not claimed as unique photography per code.
CURRENT CATALOG IMAGE
NTZ43.7
Content-distinct product asset for this code.
CURRENT CATALOG IMAGE
NTZ45.5
Content-distinct product asset for this code.
CURRENT CATALOG IMAGE
NTZ411
Content-distinct product asset for this code.
CURRENT CATALOG IMAGE
NTZ611
Content-distinct product asset for this code.| Model 50/60 Hz | Outlet mm | Motor power HP | Rated current A · 380 V | Rated capacity GPM | Rated head ft | Max capacity GPM | Max head ft | Impeller passage mm |
|---|---|---|---|---|---|---|---|---|
| NTZ32.2 | 80 | 3.0 | 5.5 | 158.5 | 32.8 | 317.0 | 39.4 | 20 |
| NTZ33.7 | 80 | 5.0 | 8.2 | 158.5 | 44.3 | 380.4 | 49.2 | 20 |
| NTZ43.7 | 100 | 5.0 | 8.2 | 264.2 | 36.1 | 501.9 | 49.2 | 20 |
| NTZ45.5 | 100 | 7.4 | 11.7 | 286.2 | 45.9 | 607.6 | 57.4 | 30 |
| NTZ411 | 100 | 14.8 | 22 | 264.2 | 78.7 | 713.3 | 88.6 | 20 |
| NTZ611 | 150 | 14.8 | 22 | 528.3 | 55.8 | 1083.1 | 73.8 | 30 |
Published data performance table has one row per model under a Model 50/60Hz heading, with separate 50 Hz and 60 Hz curves on printed page 49. Rated current is published for 380 V.
| Model | d mm | A mm | A1 mm | B mm | B1 mm | D mm | H mm | H1 mm | W1 mm | N.W. / G.W. kg | Packing mm |
|---|---|---|---|---|---|---|---|---|---|---|---|
| NTZ32.2 | 80 | 469 | 408 | 378 | 257 | 371 | 685 | 625 | 230 | 92 / 99 | 765×405×515 |
| NTZ33.7 | 80 | 469 | 408 | 378 | 257 | 371 | 750 | 690 | 230 | 108 / 116 | 830×405×515 |
| NTZ43.7 | 100 | 469 | 408 | 378 | 257 | 371 | 750 | 690 | 230 | 108 / 116 | 830×405×515 |
| NTZ45.5 | 100 | 494 | 433 | 383 | 262 | 386 | 795 | 735 | 225 | 139 / 151 | 835×425×560 |
| NTZ411 | 100 | 598 | 505 | 436 | 275 | 441 | 862 | 802 | 240 | 210 / 226 | 910×475×665 |
| NTZ611 | 150 | 598 | 505 | 436 | 275 | 441 | 862 | 802 | 240 | 210 / 226 | 910×475×665 |
Configurations
Available 50 Hz / 60 Hz electrical configurations for each model.
The current catalog lists all six published codes. Values below remain current-catalog facts and do not overwrite the published performance table. NTZ611: 60 Hz is customizable for that code.
| Exact code | Hz | Phase / V | Power HP | Rated flow / head GPM / ft | Max flow / head GPM / ft | Outlet / passage mm | N.W. kg | Cable m | Drawing |
|---|---|---|---|---|---|---|---|---|---|
| NTZ32.2 | 50 | 3 / 380 | 3.0 | 158.5 / 32.8 | 317.0 / 39.4 | 80 / 20 | 92 | 8 | View drawing |
| NTZ32.2 | 60 | 3 / 380 | 3.0 | 158.5 / 32.8 | 317.0 / 39.4 | 80 / 20 | 92 | 8 | View drawing |
| NTZ33.7 | 50 | 3 / 380 | 5.0 | 158.5 / 44.3 | 386.1 / 49.2 | 80 / 20 | 108 | 8 | View drawing |
| NTZ33.7 | 60 | 3 / 380 | 5.0 | 158.5 / 44.3 | 386.1 / 49.2 | 80 / 20 | 108 | 8 | View drawing |
| NTZ43.7 | 50 | 3 / 380 | 5.0 | 264.2 / 36.1 | 501.9 / 49.2 | 100 / 20 | 108 | 8 | View drawing |
| NTZ43.7 | 60 | 3 / 380 | 5.0 | 264.2 / 36.1 | 501.9 / 49.2 | 100 / 20 | 108 | 8 | View drawing |
| NTZ45.5 | 50 | 3 / 380 | 7.4 | 286.2 / 45.9 | 607.6 / 57.4 | 100 / 30 | 139 | 8 | View drawing |
| NTZ45.5 | 60 | 3 / 380 | 7.4 | 286.2 / 45.9 | 607.6 / 57.4 | 100 / 30 | 139 | 8 | View drawing |
| NTZ411 | 50 | 3 / 380 | 14.8 | 264.2 / 78.7 | 713.3 / 88.3 | 100 / 20 | 210 | 8 | View drawing |
| NTZ411 | 60 | 3 / 380 | 14.8 | 264.2 / 78.7 | 713.3 / 88.3 | 100 / 20 | 210 | 8 | View drawing |
| NTZ611 | 50 | 3 / 380 | 14.8 | 528.3 / 55.8 | 1083.1 / 73.8 | 150 / 30 | 210 | 8 | View drawing |
Current catalog differences: NTZ33.7 lists maximum flow of 386.1 GPM versus published 380.4 GPM; NTZ411 lists maximum head of 88.3 ft versus published 88.6 ft. NTZ611 currently has no 60 Hz catalog record; 60 Hz is customizable for that code. Confirm the approved curve before quotation.
Published data also lists other voltages and optional cable length. Those options are not inferred into current records.
Construction
Jacketed cast-iron body. High-chrome wear parts.
Printed page 48 lists the component materials below. Blank material cells are left as not stated.
- Discharge connection / upper cover / bearing houses / seal house / motor body / pump body / valve seat / seat assembly
- Cast iron
- Handle / outer casing / strainer
- Steel
- Impeller / agitator
- High chrome alloy
- Inlet plate
- Ductile iron
- Check valve
- NBR
- Rotor shaft
- AISI 420 SS
- Bearings
- Ball bearing
- Mechanical seal
- SiC-SiC / SiC-SiC
- Stator / oil seal / cable / motor protector
- Not listed in published data material table
SOURCE & REVIEW
Evidence stays tied to NTZ.
Published source
Published data printed pages 47-49 with NTZ narrative, summary specifications, applications, materials, dimensions, 50/60 Hz curves and six performance rows.
Current catalog
Eleven exact frequency records for six current model codes, five content-distinct product image paths and six dimension drawings. One series image is shared by NTZ32.2 and NTZ33.7. NTZ611 has no current 60 Hz record listed.
Confirmation
Current decimal differences, NTZ611 60 Hz customization scope, approved performance curve and final quotation scope require confirmation.
NTZ FAQ
Model boundaries, cooling jacket and quotation checks.
Is NTZ a separate Contents item?
Yes. NTZ is an independent published data Contents item on printed pages 47-49. This page keeps its six published model codes separate from adjacent Contents entries such as KBS and QNS.
Which NTZ codes are currently listed?
The current catalog has eleven records for all six published codes. NTZ611 currently lists a 50 Hz record only; 60 Hz is customizable for that code.
What low-water feature does published data claim?
Published data states that a cooling water jacket allows the pump to operate at low water level for an extended period without fear of overheating. That is a published statement, not external verification.
Why can current maxima differ from published data?
Published performance rows and current catalog records are separate sources. NTZ33.7 and NTZ411 show decimal differences between the two sources, so both remain visible.
Does NTZ publish float or single-phase rows?
No. Published data and current catalog records for this family are three-phase only. Float switch and single-phase configurations are not listed as separate counted rows.
Need slurry drainage with low-water cooling?