FCM-P · SELF-PRIMING RESIDUE DEWATERING PUMP

Prime from the surface.
Draw residue to ground level.

A portable self-priming residue pump for surface or submerged operation, supplied according to published data with a 5 m suction hose and close-fitting cast-iron suction plate.

● 2 published models · 4 current codes · 8 frequency records

MEUDY FCM-P self-priming residue dewatering pump with suction plate

POWER0.6-1.0 HP

MAX CAPACITY66 L/min

MAX HEAD36.4 ft

MAX VACUUM-73.3 kPa

Series Overview

Key specifications shared across the FCM-P series.

Water enters through the suction plate and hose, passes through the motor housing and water jacket, then discharges from the top for motor cooling. The outlet can be installed horizontally or vertically, while the side-inlet rubber check valve limits backflow after stopping.

Self-priming setupSurface or submerged operation stated in published data
Residue pickupCast-iron suction plate fits close to the ground
Flexible dischargeHorizontal or vertical discharge orientation

Model Range

Compare hydraulic performance across all available power ratings.

Published data tables identify FCM480P and FCM800P. FCME480P and FCME800P are current catalog-only codes on this page; no separate published control definition is inferred.

MEUDY FCM480P / FCM800P FCM-P catalog configuration image

CURRENT CATALOG IMAGE

FCM480P / FCM800P

Shared by standard catalog codes at both frequencies.
MEUDY FCME480P / FCME800P FCM-P catalog configuration image

CURRENT CATALOG IMAGE

FCME480P / FCME800P

Shared by FCME catalog codes; Published control details are not listed.
ModelSuction × discharge
mm
Power
kW / HP
Rated current
A
Max capacity 50 / 60 Hz
L/min
Max head
ft
Max vacuum
kPa (mmHg)
FCM480P25×250.48 / 0.653.050 / 5527.2-73.3 (-550)
FCM800P25×250.75 / 15.060 / 6636.1-73.3 (-550)
Modeld / d1 / A / D
mm
H / B / B1
mm
N.W. / G.W.
kg
Packing
mm
FCM480P25 / 138 / 308 / 261342 / 277 / 15218 / 20375×375×380
FCM800P25 / 138 / 308 / 261382 / 317 / 15220 / 22375×375×420

Configurations

Available 50 Hz / 60 Hz electrical configurations for each model.

Each exact code has one 50 Hz and one 60 Hz record. Catalog-only FCME codes remain visibly distinct from the two published models.

Exact codeHzPhase / VPower
HP
Rated flow / head
GPM / ft
Max flow / head
GPM / ft
Outlet / passage
mm
N.W.
kg
Cable
m
Drawing
FCM480P501 / 2200.66.6 / 16.414.5 / 27.225 / 6186View
FCM480P601 / 1150.66.6 / 16.414.5 / 29.225 / 6186View
FCM800P501 / 2201.08.8 / 26.215.9 / 36.125 / 6Not listed6View
FCM800P601 / 1151.08.8 / 26.217.6 / 36.425 / 6Not listed6View
FCME480P501 / 2200.66.6 / 16.414.5 / 27.225 / 6Not listed6View
FCME480P601 / 1150.66.6 / 16.414.5 / 29.225 / 6Not listed6View
FCME800P501 / 2201.08.8 / 26.215.9 / 36.125 / 6Not listed6View
FCME800P601 / 1151.08.8 / 26.217.6 / 36.425 / 6Not listed6View

Published data gives 8.3 m and 36.1 ft maximum head without a separate 60 Hz head column. Current 60 Hz records publish 8.9 m for 480 variants and 11.1 m for 800 variants. Only positive catalog weights are shown; null and zero values appear as Not listed.

LIQUID TEMPERATUREUp to 40°C
pH RANGE6.5-8.5
PROTECTIONIP68
IMMERSION DEPTHUp to 32.8 ft
CABLE6 m
SUPPLY1φ 115 V (NA default · 60 Hz)

Construction & materials

A side check valve feeding a water-jacket cooling path.

Published data lists a steel outer casing, ductile-iron impeller, rubber-and-steel diffuser, AISI 304 stainless-steel inlet plate and strainer, plus an NBR rubber ball.

Suction plate
Cast iron
Side check valve
Rubber
Impeller
Ductile iron
Diffuser
Rubber and steel
Inlet plate / strainer
AISI 304 stainless steel
Outer casing
Steel
Rubber ball
NBR
Mechanical seal
Ceramic-SiC / carbon-ceramic
Cable
H07RN-F

FCM-P FAQ

Self-priming operation and source boundaries.

Can the FCM-P operate above or below the water surface?

Published data describes FCM-P as a self-priming pump designed for both surface and submerged operation.

What is supplied for residue pickup?

Published data states that the pump is supplied with a 5 m suction hose and a cast-iron suction plate designed to fit close to the ground.

How is backflow limited?

A rubber check valve at the side water inlet helps prevent water from flowing back after the pump stops.

Why are FCME480P and FCME800P included?

The current English catalog places these exact codes in the FCM-P series. Published data does not provide separate FCME-P hydraulic, dimension or control rows, so they are shown only as catalog configurations and drawing links.

Why are several current weights shown as Not listed?

Only FCM480P has a positive current catalog weight. Null and zero values for the other codes are treated as missing data rather than published as 0 kg.

How should 50 Hz and 60 Hz performance be compared?

Published data gives separate maximum capacities of 50/55 L/min for FCM480P and 60/66 L/min for FCM800P. Current records preserve frequency-specific maximum flow and head values in the configuration table.

Need surface or submerged residue pickup?

Move from the FCM-P family to a reviewed frequency configuration.