FCM-P · SELF-PRIMING RESIDUE DEWATERING PUMP
Prime from the surface.
Draw residue to ground level.
A portable self-priming residue pump for surface or submerged operation, supplied according to published data with a 5 m suction hose and close-fitting cast-iron suction plate.
● 2 published models · 4 current codes · 8 frequency records

POWER0.6-1.0 HP
MAX CAPACITY66 L/min
MAX HEAD36.4 ft
MAX VACUUM-73.3 kPa
Series Overview
Key specifications shared across the FCM-P series.
Water enters through the suction plate and hose, passes through the motor housing and water jacket, then discharges from the top for motor cooling. The outlet can be installed horizontally or vertically, while the side-inlet rubber check valve limits backflow after stopping.
Model Range
Compare hydraulic performance across all available power ratings.
Published data tables identify FCM480P and FCM800P. FCME480P and FCME800P are current catalog-only codes on this page; no separate published control definition is inferred.

CURRENT CATALOG IMAGE
FCM480P / FCM800P
Shared by standard catalog codes at both frequencies.
CURRENT CATALOG IMAGE
FCME480P / FCME800P
Shared by FCME catalog codes; Published control details are not listed.| Model | Suction × discharge mm | Power kW / HP | Rated current A | Max capacity 50 / 60 Hz L/min | Max head ft | Max vacuum kPa (mmHg) |
|---|---|---|---|---|---|---|
| FCM480P | 25×25 | 0.48 / 0.65 | 3.0 | 50 / 55 | 27.2 | -73.3 (-550) |
| FCM800P | 25×25 | 0.75 / 1 | 5.0 | 60 / 66 | 36.1 | -73.3 (-550) |
| Model | d / d1 / A / D mm | H / B / B1 mm | N.W. / G.W. kg | Packing mm |
|---|---|---|---|---|
| FCM480P | 25 / 138 / 308 / 261 | 342 / 277 / 152 | 18 / 20 | 375×375×380 |
| FCM800P | 25 / 138 / 308 / 261 | 382 / 317 / 152 | 20 / 22 | 375×375×420 |
Configurations
Available 50 Hz / 60 Hz electrical configurations for each model.
Each exact code has one 50 Hz and one 60 Hz record. Catalog-only FCME codes remain visibly distinct from the two published models.
| Exact code | Hz | Phase / V | Power HP | Rated flow / head GPM / ft | Max flow / head GPM / ft | Outlet / passage mm | N.W. kg | Cable m | Drawing |
|---|---|---|---|---|---|---|---|---|---|
| FCM480P | 50 | 1 / 220 | 0.6 | 6.6 / 16.4 | 14.5 / 27.2 | 25 / 6 | 18 | 6 | View |
| FCM480P | 60 | 1 / 115 | 0.6 | 6.6 / 16.4 | 14.5 / 29.2 | 25 / 6 | 18 | 6 | View |
| FCM800P | 50 | 1 / 220 | 1.0 | 8.8 / 26.2 | 15.9 / 36.1 | 25 / 6 | Not listed | 6 | View |
| FCM800P | 60 | 1 / 115 | 1.0 | 8.8 / 26.2 | 17.6 / 36.4 | 25 / 6 | Not listed | 6 | View |
| FCME480P | 50 | 1 / 220 | 0.6 | 6.6 / 16.4 | 14.5 / 27.2 | 25 / 6 | Not listed | 6 | View |
| FCME480P | 60 | 1 / 115 | 0.6 | 6.6 / 16.4 | 14.5 / 29.2 | 25 / 6 | Not listed | 6 | View |
| FCME800P | 50 | 1 / 220 | 1.0 | 8.8 / 26.2 | 15.9 / 36.1 | 25 / 6 | Not listed | 6 | View |
| FCME800P | 60 | 1 / 115 | 1.0 | 8.8 / 26.2 | 17.6 / 36.4 | 25 / 6 | Not listed | 6 | View |
Published data gives 8.3 m and 36.1 ft maximum head without a separate 60 Hz head column. Current 60 Hz records publish 8.9 m for 480 variants and 11.1 m for 800 variants. Only positive catalog weights are shown; null and zero values appear as Not listed.
Construction & materials
A side check valve feeding a water-jacket cooling path.
Published data lists a steel outer casing, ductile-iron impeller, rubber-and-steel diffuser, AISI 304 stainless-steel inlet plate and strainer, plus an NBR rubber ball.
- Suction plate
- Cast iron
- Side check valve
- Rubber
- Impeller
- Ductile iron
- Diffuser
- Rubber and steel
- Inlet plate / strainer
- AISI 304 stainless steel
- Outer casing
- Steel
- Rubber ball
- NBR
- Mechanical seal
- Ceramic-SiC / carbon-ceramic
- Cable
- H07RN-F
FCM-P FAQ
Self-priming operation and source boundaries.
Can the FCM-P operate above or below the water surface?
Published data describes FCM-P as a self-priming pump designed for both surface and submerged operation.
What is supplied for residue pickup?
Published data states that the pump is supplied with a 5 m suction hose and a cast-iron suction plate designed to fit close to the ground.
How is backflow limited?
A rubber check valve at the side water inlet helps prevent water from flowing back after the pump stops.
Why are FCME480P and FCME800P included?
The current English catalog places these exact codes in the FCM-P series. Published data does not provide separate FCME-P hydraulic, dimension or control rows, so they are shown only as catalog configurations and drawing links.
Why are several current weights shown as Not listed?
Only FCM480P has a positive current catalog weight. Null and zero values for the other codes are treated as missing data rather than published as 0 kg.
How should 50 Hz and 60 Hz performance be compared?
Published data gives separate maximum capacities of 50/55 L/min for FCM480P and 60/66 L/min for FCM800P. Current records preserve frequency-specific maximum flow and head values in the configuration table.
Need surface or submerged residue pickup?