Products/High temperature/B-HT

B-HT · HIGH-TEMPERATURE SUBMERSIBLE SEWAGE PUMP

B-HT high-temperature sewage pump

One product family with sixteen hydraulic models and sixteen current 50 Hz catalog configurations for liquids up to 80°C.

Published pages 81-84 · 16 hydraulic rows · 16 current catalog records

POWER1.0-20.1HPLIQUID80°C maxMAX FLOW880.6GPMMAX HEAD154.2ft
MEUDY B-HT 150B215HT high-temperature submersible sewage pump
Current English catalog image assigned to 150B211HT and 150B215HT

Series Overview

Key specifications shared across the B-HT series.

R / Y / ZSoft pipe, hard pipe or auto-coupled
Class HHigh-temperature insulation
8 mChloroprene cable
10 mMaximum immersion depth

Published data describes upgraded motor insulation, rubber, bearings and lubrication compared with the standard 40°C type. It specifies IP68 protection, pH 6-10 and three-phase 380 V +/-10% at 50 Hz and 60 Hz; the current English catalog presently publishes only 50 Hz records. North American pages show motor power in HP, flow in GPM and head in ft.

Model Range

Compare hydraulic performance across all available power ratings.

Sixteen published models, 50 Hz and 60 Hz kept separate. Each frequency cell shows published rated flow / head and maximum flow / head in GPM / ft. Current catalog availability is shown in the next table.

ModelMotor
HP
Outlet
mm
50 Hz rated / max
GPM / ft
60 Hz rated / max
GPM / ft
Passage
mm
N.W.
kg
50B2.75HT1.05044.0 / 32.8
114.5 / 39.4
44.0 / 32.8
114.5 / 39.4
2522
50B21.1HT1.55066.0 / 32.8
145.3 / 49.2
66.0 / 32.8
145.3 / 49.2
2524
50B21.5HT2.05066.0 / 49.2
162.9 / 65.6
66.0 / 49.2
162.9 / 65.6
2040
50B22.2HT3.05066.0 / 65.6
176.1 / 72.2
66.0 / 65.6
176.1 / 72.2
2042
80B22.2HT3.080176.1 / 29.5
281.8 / 52.5
176.1 / 29.5
281.8 / 52.5
3047
50B23.0HT4.050110.1 / 65.6
198.1 / 85.3
110.1 / 65.6
198.1 / 85.3
2050
80B23.0HT4.080176.1 / 42.7
330.2 / 65.6
176.1 / 42.7
330.2 / 65.6
3055
80B24.0HT5.480176.1 / 59.1
356.6 / 78.7
176.1 / 59.1
356.6 / 78.7
3062
80B25.5HT7.480198.1 / 65.6
387.5 / 91.9
198.1 / 65.6
387.5 / 91.9
3577.5
100B25.5HT7.4100286.2 / 49.2
484.3 / 82.0
286.2 / 49.2
484.3 / 82.0
3081.5
80B27.5HT10.180176.1 / 98.4
352.2 / 131.2
176.1 / 98.4
352.2 / 131.2
3094
100B27.5HT10.1100286.2 / 65.6
550.4 / 108.3
286.2 / 65.6
550.4 / 108.3
3596
100B211HT14.8100286.2 / 98.4
528.3 / 144.4
286.2 / 98.4
528.3 / 144.4
35135
150B211HT14.8150440.3 / 65.6
880.6 / 95.1
440.3 / 62.3
814.5 / 88.6
50147
100B215HT20.1100286.2 / 114.8
616.4 / 154.2
286.2 / 114.8
616.4 / 154.2
30159
150B215HT20.1150440.3 / 91.9
880.6 / 141.1
440.3 / 91.9
880.6 / 141.1
45171

For each frequency column, the first line is rated flow / head and the second is maximum flow / head. Only 150B211HT has distinct 50/60 Hz table values.

MEUDY B-HT 50B2.75HT high-temperature sewage pump catalog image

50 MM · 0.75 KW

50B2.75HT

One of nine content-distinct product images assigned by current English B-HT records.
MEUDY B-HT 50B21.1HT, 50B21.5HT high-temperature sewage pump catalog image

50 MM · 1.1-1.5 KW

50B21.1HT / 50B21.5HT

One of nine content-distinct product images assigned by current English B-HT records.
MEUDY B-HT 50B22.2HT, 50B23.0HT high-temperature sewage pump catalog image

50 MM · 2.2-3.0 KW

50B22.2HT / 50B23.0HT

One of nine content-distinct product images assigned by current English B-HT records.
MEUDY B-HT 80B22.2HT, 80B23.0HT high-temperature sewage pump catalog image

80 MM · 2.2-3.0 KW

80B22.2HT / 80B23.0HT

One of nine content-distinct product images assigned by current English B-HT records.
MEUDY B-HT 80B24.0HT, 80B25.5HT high-temperature sewage pump catalog image

80 MM · 4.0-5.5 KW

80B24.0HT / 80B25.5HT

One of nine content-distinct product images assigned by current English B-HT records.
MEUDY B-HT 100B25.5HT high-temperature sewage pump catalog image

100 MM · 5.5 KW

100B25.5HT

One of nine content-distinct product images assigned by current English B-HT records.
MEUDY B-HT 80B27.5HT high-temperature sewage pump catalog image

80 MM · 7.5 KW

80B27.5HT

One of nine content-distinct product images assigned by current English B-HT records.
MEUDY B-HT 100B27.5HT, 100B211HT, 100B215HT high-temperature sewage pump catalog image

100 MM · 7.5-15 KW

100B27.5HT / 100B211HT / 100B215HT

One of nine content-distinct product images assigned by current English B-HT records.
MEUDY B-HT 150B211HT, 150B215HT high-temperature sewage pump catalog image

150 MM · 11-15 KW

150B211HT / 150B215HT

One of nine content-distinct product images assigned by current English B-HT records.

Configurations

Available 50 Hz / 60 Hz electrical configurations for each model.

Every published record is three-phase 380 V and lists 80°C maximum liquid temperature. 60 Hz is available as a customization; the table shows published catalog records only.

Exact codeHzPower
HP
Outlet
mm
Rated flow / head
GPM / ft
Max flow / head
GPM / ft
Passage
mm
Temperature
°C max
Drawing
50B2.75HT501.05044.0 / 32.8112.7 / 39.02580View
50B21.1HT501.55066.0 / 32.8137.8 / 45.92580View
50B21.5HT502.05066.0 / 49.2144.9 / 61.02080View
50B22.2HT503.05066.0 / 65.6170.0 / 71.22080View
80B22.2HT503.080176.1 / 29.5291.0 / 53.53080View
50B23.0HT504.050110.1 / 65.6189.3 / 85.62080View
80B23.0HT504.080176.1 / 42.7359.3 / 64.33080View
80B24.0HT505.480176.1 / 59.1377.3 / 78.73080View
80B25.5HT507.480198.1 / 65.6387.5 / 91.93580View
100B25.5HT507.4100286.2 / 49.2484.3 / 82.03080View
80B27.5HT5010.180176.1 / 98.4333.3 / 131.23080View
100B27.5HT5010.1100286.2 / 65.6550.4 / 106.63580View
100B211HT5014.8100286.2 / 98.4528.3 / 144.43580View
150B211HT5014.8150440.3 / 65.6880.6 / 95.15080View
100B215HT5020.1100286.2 / 114.8615.5 / 154.23080View
150B215HT5020.1150440.3 / 91.9880.6 / 142.14580View

Current catalog differences are not normalized to published rounding. Examples: 50B21.5HT lists 144.9 / 61.0 instead of 162.9 / 65.6, while 80B23.0HT lists 359.3 / 64.3 instead of 330.2 / 65.6 GPM / ft maximum flow / head. All sixteen 60 Hz configuration records remain unavailable. Confirm an approved curve before quotation.

Dimension drawing for MEUDY 150B215HT 50 Hz configurationRepresentative catalog drawing · 150B215HT · 50 Hz

80°C Service Package

Heat-resistant motor, seals and lubrication.

Insulation
Class H
Cable jacket
Chloroprene rubber
Mechanical seal / O-ring
FPM (FKM)
Lubricant
Turbine oil, ISO VG46
Bearings
Grease for high-temperature use
Protection
IP68

SOURCE & REVIEW

Evidence stays tied to this B-HT entry.

01

Published source

MEUDY sewage pump catalog 2026.6.6, printed pages 81-84 with 80°C specification, 50/60 Hz curves, R/Y dimensions and Z auto-coupling dimensions.

02

Current catalog

Sixteen exact 50 Hz model, outlet, passage, temperature, product-image and dimension assignments come from current English B-HT records.

03

Confirmation

Missing 60 Hz records, performance differences, certification scope and North American suitability require confirmation.

B-HT FAQ

Selection questions answered from evidence.

Which models are in the B-HT range?

Published data and current English catalog identify sixteen exact B-HT codes from 50B2.75HT through 150B215HT, covering 0.75-15 kW and 50-150 mm outlets.

Can B-HT handle liquids at 80°C?

Yes. Published data and every matching current catalog record state a maximum liquid temperature of 80°C. Published data specifies class H insulation, chloroprene cable, FPM (FKM) seals and O-rings, ISO VG46 turbine oil and high-temperature bearing grease.

Does the current catalog publish B-HT at 60 Hz?

60 Hz is customizable. Published data provides 50 Hz and 60 Hz curves; the current English catalog publishes sixteen matching 50 Hz records. Confirm the approved 60 Hz configuration when ordering a customized frequency.

Does 150B211HT have different published values by frequency?

Yes. Published data lists rated flow / head of 440 / 65.6 GPM/ft at 50 Hz and 440 / 62.3 GPM/ft at 60 Hz, with maximum flow / head of 881 / 95.1 and 815 / 88.6 GPM/ft respectively.

Why do some catalog maxima differ from published data?

Published data publishes rounded table values, while current 50 Hz records include decimal endpoints and several material differences, including 50B21.5HT and 80B23.0HT. Use an approved curve before quotation.

Continue from published data to a reviewed selection

Confirm temperature, frequency and duty point.