Products/Sewage/B 11-22 kW 4P

B SERIES · 4-POLE SUBMERSIBLE SEWAGE PUMP

B 11-22 kW 4P
sewage pump range

One product family with 13 hydraulic selections, 100-250 mm outlets and separate 50 Hz and 60 Hz performance curves.

Published pages 25-28 · 13 exact codes · 25 catalog records

POWER14.8-29.5HPOUTLET100-250mmMAX FLOW3346.2GPMMAX HEAD144.4ft
MEUDY 100B411 and 100B415 B series four-pole submersible sewage pump
Catalog image assigned to 100B411 and 100B415 · exact construction varies by model

Series Overview

Key specifications shared across the B 11-22 kW series.

RMovable soft-pipe installation
YHard-pipe installation
ZAuto-coupled installation
20 mMaximum immersion depth

The shared B-series description covers channel-impeller pumps for industrial or commercial wastewater, domestic sewage and stormwater drainage, and sewage-treatment or farm discharge. This four-pole group is rated for liquid temperature up to 40°C, pH 6-10 and an 8 m cable. North American pages show motor power in HP, flow in GPM and head in ft.

Model Range

Compare hydraulic performance across all available power ratings.

Four outlets, thirteen selections. Rated and maximum columns show flow / head in GPM / ft. Use the separate 50 Hz or 60 Hz curve for final duty-point review.

ModelMotor
HP
Outlet
mm
Rated flow / head
GPM / ft
Max flow / head
GPM / ft
Passage
mm
100B41114.8100440.3 / 72.2836.6 / 101.750
150B41114.8150660.4 / 49.21144.8 / 78.765
200B41114.82001320.9 / 29.51981.3 / 55.870
100B41520.1100440.3 / 88.6924.6 / 114.850
150B41520.1150660.4 / 65.61276.8 / 95.165
200B41520.12001320.9 / 39.42157.4 / 68.970
100B41925.5100440.3 / 101.7880.6 / 124.750
150B41925.5150660.4 / 78.71320.9 / 105.060
200B41925.52001320.9 / 49.22333.5 / 82.070
100B42229.5100440.3 / 118.1968.6 / 144.450
150B42229.5150660.4 / 91.91453.0 / 128.060
200B42229.52001320.9 / 59.12421.6 / 88.670
250B42229.52502201.4 / 36.13346.2 / 72.290

These values summarize published data table, not guaranteed operating points. Confirm the full curve at the required frequency before selection.

MEUDY 100B411 and 100B415 B four-pole sewage pump catalog image

AVAILABLE CATALOG IMAGE

100B411 / 100B415

Image assignment follows the current English catalog; frequency records and adjacent codes may share photography.
MEUDY 100B411 and 100B415 B four-pole sewage pump catalog image

AVAILABLE CATALOG IMAGE

100B411 / 100B415

Image assignment follows the current English catalog; frequency records and adjacent codes may share photography.
MEUDY 100B419 and 100B422 B four-pole sewage pump catalog image

AVAILABLE CATALOG IMAGE

100B419 / 100B422

Image assignment follows the current English catalog; frequency records and adjacent codes may share photography.
MEUDY 100B419 and 100B422 B four-pole sewage pump catalog image

AVAILABLE CATALOG IMAGE

100B419 / 100B422

Image assignment follows the current English catalog; frequency records and adjacent codes may share photography.
MEUDY 150B411 and 150B415 B four-pole sewage pump catalog image

AVAILABLE CATALOG IMAGE

150B411 / 150B415

Image assignment follows the current English catalog; frequency records and adjacent codes may share photography.
MEUDY 150B411 and 150B415 B four-pole sewage pump catalog image

AVAILABLE CATALOG IMAGE

150B411 / 150B415

Image assignment follows the current English catalog; frequency records and adjacent codes may share photography.
MEUDY 150B419 and 150B422 B four-pole sewage pump catalog image

AVAILABLE CATALOG IMAGE

150B419 / 150B422

Image assignment follows the current English catalog; frequency records and adjacent codes may share photography.
MEUDY 150B419 and 150B422 B four-pole sewage pump catalog image

AVAILABLE CATALOG IMAGE

150B419 / 150B422

Image assignment follows the current English catalog; frequency records and adjacent codes may share photography.
MEUDY 200B411 and 200B415 B four-pole sewage pump catalog image

AVAILABLE CATALOG IMAGE

200B411 / 200B415

Image assignment follows the current English catalog; frequency records and adjacent codes may share photography.
MEUDY 200B411 and 200B415 B four-pole sewage pump catalog image

AVAILABLE CATALOG IMAGE

200B411 / 200B415

Image assignment follows the current English catalog; frequency records and adjacent codes may share photography.
MEUDY 200B419 and 200B422 B four-pole sewage pump catalog image

AVAILABLE CATALOG IMAGE

200B419 / 200B422

Image assignment follows the current English catalog; frequency records and adjacent codes may share photography.
MEUDY 200B419 and 200B422 B four-pole sewage pump catalog image

AVAILABLE CATALOG IMAGE

200B419 / 200B422

Image assignment follows the current English catalog; frequency records and adjacent codes may share photography.
MEUDY 250B422 B four-pole sewage pump catalog image

AVAILABLE CATALOG IMAGE

250B422

Image assignment follows the current English catalog; frequency records and adjacent codes may share photography.

Configurations

Available 50 Hz / 60 Hz electrical configurations for each model.

The current English catalog contains 25 records. The absent 250B422 60 Hz entry and the three 19 kW voltage conflicts require confirmation.

Exact codeHzPhase / VPower
HP
Outlet
mm
Rated flow / head
GPM / ft
Max flow / head
GPM / ft
Drawing
100B411503 / 38014.8-440.3 / 72.2836.6 / 101.7View
100B411603 / 38014.8100440.3 / 72.2836.6 / 94.2View
100B415503 / 38020.1-440.3 / 88.6924.6 / 115.2View
100B415603 / 38020.1100440.3 / 88.6902.6 / 114.2View
100B419503 / 38025.5-440.3 / 101.7880.6 / 127.3View
100B419603 / 22025.5100440.3 / 101.7880.6 / 127.3View
100B422503 / 38029.5-440.3 / 118.1968.6 / 145.3View
100B422603 / 38029.5100440.3 / 118.1968.6 / 145.3View
150B411503 / 38014.8-660.4 / 49.21144.8 / 78.7View
150B411603 / 38014.8150660.4 / 49.21144.8 / 78.4View
150B415503 / 38020.1-660.4 / 65.61276.8 / 96.5View
150B415603 / 38020.1150660.4 / 65.61320.9 / 94.8View
150B419503 / 38025.5-660.4 / 78.71320.9 / 106.0View
150B419603 / 22025.5150660.4 / 82.01320.9 / 106.3View
150B422503 / 38029.5-660.4 / 91.91453.0 / 128.3View
150B422603 / 38029.5150660.4 / 91.91453.0 / 125.3View
200B411503 / 38014.8-1320.9 / 29.51981.3 / 55.8View
200B411603 / 38014.82001320.9 / 29.52091.4 / 56.4View
200B415503 / 38020.1-1320.9 / 39.42157.4 / 67.9View
200B415603 / 38020.12001320.9 / 39.42157.4 / 67.6View
200B419503 / 38025.5-1320.9 / 49.22333.5 / 80.7View
200B419603 / 22025.52001320.9 / 49.22245.5 / 80.7View
200B422503 / 38029.5-1320.9 / 59.12427.8 / 88.9View
200B422603 / 38029.52001320.9 / 59.12377.6 / 88.6View
250B422503 / 38029.5-2201.4 / 36.13346.2 / 72.8View

Published data shows both frequency curves, but the current catalog has no 60 Hz record for 250B422. It also lists 220 V for the three 19 kW 60 Hz records while published data group specification states 380 V ±10%. Do not substitute or reconcile these values without written confirmation.

Dimension drawing for MEUDY 100B411 50 Hz configurationRepresentative drawing · 100B411 · 50 Hz

Construction

Cast-iron body, ductile-iron impeller.

Pump body
Cast iron
Impeller
Ductile iron
Shaft
AISI 420 stainless steel
Mechanical seal
SiC-SiC
Insulation / protection
Class F / IP68
Optional probes
Overheat / oil-water leakage

SOURCE & REVIEW

Evidence stays tied to this group.

01

Published source

MEUDY sewage pump catalog 2026.6.6, shared B applications on page 4 and this product group on pages 25-28.

02

Current catalog

Exact frequency, voltage, image and dimension assignments come from current English catalog records; conflicting values are retained rather than normalized.

03

Confirmation

The missing 250B422 60 Hz record, 19 kW voltage conflict, certification scope, North American electrical suitability and coupling supply require written confirmation.

B SERIES FAQ

Selection questions answered from evidence.

How many hydraulic selections are in this B 11-22 kW 4P range?

The published data table lists 13 hydraulic selections across 100 mm, 150 mm, 200 mm and 250 mm outlets.

Does published data provide both 50 Hz and 60 Hz performance curves?

Yes. Published data presents separate 50 Hz and 60 Hz curves and identifies synchronous speeds of 1,500 rpm and 1,800 rpm respectively.

Does every model have both frequency records in the current catalog?

No. The current English catalog contains 25 records: 12 exact codes have both 50 Hz and 60 Hz entries, while 250B422 currently has only a 50 Hz entry.

Which voltage should be used for the 19 kW 60 Hz models?

Confirmation is required. Published data group specification states 380 V ±10% at 60 Hz, while the current catalog records for 100B419, 150B419 and 200B419 state 220 V.

Compare adjacent B product groups

Move from published data range to a reviewed duty point.