Products/Sewage/B Type A

B SERIES · TYPE A · SUBMERSIBLE SEWAGE PUMP

B 0.75-1.5 kW 2P
Type A sewage pump

A separate product family with seven hydraulic selections, 50 mm or 65 mm outlets and soft-pipe, hard-pipe or auto-coupled installation arrangements.

Published pages 9-12 · 21 exact codes · 37 frequency and electrical records

POWER1.0-2.0HPOUTLET50-65mmMAX FLOW211.3GPMMAX HEAD68.9ft
MEUDY 50B2.75SA B Type A submersible sewage pump
Representative Type A catalog image · exact supplied configuration varies

Series Overview

Key specifications shared across the B 0.75-1.5 kW 2P Type A series.

RMovable soft-pipe installation
YHard-pipe installation
ZAuto-coupled installation
IP68Protection class

The shared B-series published page describes a channel impeller with a wide passage and lists industrial or commercial wastewater, domestic sewage and stormwater drainage, and sewage-treatment or farm discharge applications. The Type A construction shows a side discharge connection and cast-iron hydraulic and motor components. Published limits are liquid temperature up to 40°C, pH 6-10, immersion depth up to 10 m and an 8 m cable. Final connection, coupling and accessory scope depend on the quoted configuration. North American pages show motor power in HP, flow in GPM and head in ft.

Model Range

Compare hydraulic performance across all available power ratings.

Published data rows pair three-phase and single-phase versions around seven hydraulic duties. L-marked rows remain separate because their rated flow and head differ.

Hydraulic modelMotor
HP
Outlet
mm
Rated flow / head
GPM / ft
Max flow / head
GPM / ft
Passage
mm
50B2.75A1.05044.0 / 32.8114.5 / 39.425
50B21.1A1.55035.2 / 49.2127.7 / 59.120
65B21.1A1.56566.0 / 32.8145.3 / 49.225
65B21.1AL1.565110.1 / 26.2180.5 / 42.725
50B21.5A2.05035.2 / 62.3145.3 / 68.920
65B21.5A2.06566.0 / 49.2162.9 / 65.625
65B21.5AL2.065110.1 / 36.1211.3 / 52.525

These are published reference points, not guaranteed operating points. Use the complete curve for the required frequency and duty.

MEUDY 50B2.75A and 50B2.75SA B Type A sewage pump catalog image

AVAILABLE CATALOG IMAGE

50B2.75A / 50B2.75SA

Image assignment follows the current English catalog; shared photography is identified by the listed codes.
MEUDY 50B2.75A and 50B2.75SA B Type A sewage pump catalog image

AVAILABLE CATALOG IMAGE

50B2.75A / 50B2.75SA

Image assignment follows the current English catalog; shared photography is identified by the listed codes.
MEUDY 50B2.75SAF B Type A sewage pump catalog image

AVAILABLE CATALOG IMAGE

50B2.75SAF

Image assignment follows the current English catalog; shared photography is identified by the listed codes.
MEUDY 50B2.75SAF B Type A sewage pump catalog image

AVAILABLE CATALOG IMAGE

50B2.75SAF

Image assignment follows the current English catalog; shared photography is identified by the listed codes.
MEUDY 50B21.1A and 50B21.1SA and 50B21.5A and 50B21.5SA B Type A sewage pump catalog image

AVAILABLE CATALOG IMAGE

50B21.1A / 50B21.1SA / 50B21.5A / 50B21.5SA

Image assignment follows the current English catalog; shared photography is identified by the listed codes.
MEUDY 50B21.1A and 50B21.1SA and 50B21.5A and 50B21.5SA B Type A sewage pump catalog image

AVAILABLE CATALOG IMAGE

50B21.1A / 50B21.1SA / 50B21.5A / 50B21.5SA

Image assignment follows the current English catalog; shared photography is identified by the listed codes.
MEUDY 50B21.1SAF and 50B21.5SAF B Type A sewage pump catalog image

AVAILABLE CATALOG IMAGE

50B21.1SAF / 50B21.5SAF

Image assignment follows the current English catalog; shared photography is identified by the listed codes.
MEUDY 50B21.1SAF and 50B21.5SAF B Type A sewage pump catalog image

AVAILABLE CATALOG IMAGE

50B21.1SAF / 50B21.5SAF

Image assignment follows the current English catalog; shared photography is identified by the listed codes.
MEUDY 65B21.1A and 65B21.1SA and 65B21.5A and 65B21.5SA B Type A sewage pump catalog image

AVAILABLE CATALOG IMAGE

65B21.1A / 65B21.1SA / 65B21.5A / 65B21.5SA

Image assignment follows the current English catalog; shared photography is identified by the listed codes.
MEUDY 65B21.1AL and 65B21.1SAL and 65B21.5AL and 65B21.5SAL B Type A sewage pump catalog image

AVAILABLE CATALOG IMAGE

65B21.1AL / 65B21.1SAL / 65B21.5AL / 65B21.5SAL

Image assignment follows the current English catalog; shared photography is identified by the listed codes.
MEUDY 65B21.1AL and 65B21.5AL B Type A sewage pump catalog image

AVAILABLE CATALOG IMAGE

65B21.1AL / 65B21.5AL

Image assignment follows the current English catalog; shared photography is identified by the listed codes.
MEUDY 65B21.1SA and 65B21.5A and 65B21.5SA B Type A sewage pump catalog image

AVAILABLE CATALOG IMAGE

65B21.1SA / 65B21.5A / 65B21.5SA

Image assignment follows the current English catalog; shared photography is identified by the listed codes.
MEUDY 65B21.1SAF and 65B21.5SAF B Type A sewage pump catalog image

AVAILABLE CATALOG IMAGE

65B21.1SAF / 65B21.5SAF

Image assignment follows the current English catalog; shared photography is identified by the listed codes.
MEUDY 65B21.1SAF and 65B21.5SAF B Type A sewage pump catalog image

AVAILABLE CATALOG IMAGE

65B21.1SAF / 65B21.5SAF

Image assignment follows the current English catalog; shared photography is identified by the listed codes.
MEUDY 65B21.1SALF and 65B21.5SALF B Type A sewage pump catalog image

AVAILABLE CATALOG IMAGE

65B21.1SALF / 65B21.5SALF

Image assignment follows the current English catalog; shared photography is identified by the listed codes.

Configurations

Available 50 Hz / 60 Hz electrical configurations for each model.

The current English catalog exposes 21 exact codes and 37 frequency/electrical records. Each dimension link belongs to that specific record.

Exact codeHzPhase / VPower
HP
Outlet
mm
Rated flow / head
GPM / ft
Max flow / head
GPM / ft
Drawing
50B2.75A503 / 3801.0-44.0 / 32.8114.5 / 38.7View
50B2.75A603 / 3801.05044.0 / 32.8114.5 / 40.0View
50B2.75SA501 / 2201.0-44.0 / 32.8114.5 / 38.7View
50B2.75SA601 / 1151.05044.0 / 32.8114.5 / 39.0View
50B2.75SAF501 / 2201.0-44.0 / 32.8114.5 / 38.7View
50B2.75SAF601 / 1151.05044.0 / 32.8114.5 / 39.0View
50B21.1A503 / 3801.5-35.2 / 49.2127.7 / 58.4View
50B21.1A603 / 3801.55035.2 / 49.2127.7 / 59.7View
50B21.1SA501 / 2201.5-35.2 / 49.2127.7 / 58.4View
50B21.1SA601 / 1151.55035.2 / 49.2127.7 / 58.7View
50B21.1SAF501 / 2201.5-35.2 / 49.2127.7 / 58.4View
50B21.1SAF601 / 1151.55035.2 / 49.2127.7 / 58.7View
50B21.5A503 / 3802.0-35.2 / 62.3144.4 / 68.6View
50B21.5A603 / 3802.05035.2 / 62.3145.3 / 69.9View
50B21.5SA501 / 2202.0-35.2 / 62.3144.4 / 68.9View
50B21.5SA601 / 1152.05035.2 / 62.3145.3 / 69.6View
50B21.5SAF501 / 2202.0-35.2 / 62.3144.4 / 68.9View
50B21.5SAF601 / 1152.05035.2 / 62.3145.3 / 69.6View
65B21.1A503 / 3801.5-66.0 / 32.8145.3 / 48.9View
65B21.1AL503 / 3801.5-110.1 / 26.2180.5 / 42.7View
65B21.1AL603 / 3801.565110.1 / 26.2180.5 / 42.0View
65B21.1SA501 / 2201.5-66.0 / 32.8145.3 / 47.9View
65B21.1SA601 / 1151.56566.0 / 32.8145.3 / 47.9View
65B21.1SAF501 / 2201.5-66.0 / 32.8145.3 / 47.9View
65B21.1SAF601 / 1151.56566.0 / 32.8145.3 / 47.9View
65B21.1SAL501 / 2201.5-110.1 / 26.2180.5 / 42.7View
65B21.1SALF501 / 2201.5-110.1 / 26.2180.5 / 42.7View
65B21.5A503 / 3802.0-66.0 / 49.2169.1 / 63.6View
65B21.5A603 / 3802.06566.0 / 49.2162.9 / 63.3View
65B21.5AL503 / 3802.0-110.1 / 36.1214.9 / 52.8View
65B21.5AL603 / 3802.065110.1 / 36.1211.3 / 53.1View
65B21.5SA501 / 2202.0-66.0 / 49.2167.8 / 63.3View
65B21.5SA601 / 1152.06566.0 / 49.2162.9 / 63.0View
65B21.5SAF501 / 2202.0-66.0 / 49.2167.8 / 63.3View
65B21.5SAF601 / 1152.06566.0 / 49.2162.9 / 63.0View
65B21.5SAL501 / 2202.0-110.1 / 36.1213.5 / 52.8View
65B21.5SALF501 / 2202.0-110.1 / 36.1213.5 / 52.8View

Published data explicitly defines SAF and SALF as single-phase versions with float switch. L-marked codes are retained as distinct hydraulic records without inferring any broader suffix rule. Confirm voltage, availability, accessories and complete curves before ordering.

Dimension drawing for MEUDY 50B2.75A Type A configurationRepresentative drawing · 50B2.75A

Construction

Installation choice stays visible.

Pump body
Cast iron
Impeller
Cast iron
Shaft
AISI 304 stainless steel
Mechanical seal
SiC-ceramic / carbon-ceramic
Cable length
8 m
Installation forms
R / Y / Z

SOURCE & REVIEW

Evidence and quotation boundary.

01

Published source

MEUDY sewage pump catalog 2026.6.6, shared B-series characteristics and applications on page 4, plus Type A construction, curves, dimensions and installation forms on pages 9-12.

02

Current catalog

Exact voltage, phase, frequency, image and dimension assignments come from the current English catalog records.

03

Confirmation

Certification scope, North American electrical suitability, supplied coupling, availability and final duty-point selection require written confirmation.

TYPE A FAQ

Questions before configuration.

How many hydraulic selections are in this B Type A range?

The published data table contains seven distinct rated flow and head selections across 50 mm and 65 mm outlets.

Which installation forms are shown for B Type A pumps?

Published data shows movable soft-pipe installation (R), hard-pipe installation (Y) and auto-coupled installation (Z). Confirm the supplied connection and coupling scope in the quotation.

What do SAF and SALF mean in this range?

Published data explicitly identifies B...SAF and B...SALF as single-phase configurations with a float switch.

Are 50 Hz and 60 Hz Type A configurations interchangeable?

No. Both frequencies are published, but their catalog records and full performance curves must be reviewed separately for the selected code.

Compare adjacent B product groups

Choose Type A only when its hydraulic and installation form fit the project.